6-LOGIC TROUBLE SHOOTING SEQUENCE
N.B.
Before carrying out any test disconnect braking resistor R on the contractor. Reconnect R only at calibration of testing.
When the power or computer board requires replacement, repeat the self-calibration of the balancing machine.
N.B.
When the computer board is replaced , preset the machine parameters indicated on relative nameplate.
6.1-CHECKING AND SETTING OF STATIC VALUE (STI)
N
Y
Carry out self-calibration
Wheel balancing.
Tolerance 1 gram
Select STATIC.
Apply 100 grams on inside.
Perform the spin.
Is the STATIC value on
the inside between 98 and
102 grams?
Select function “SELECTON OF MACHINE
PARAMETERS”.
Increase value “1” if the inside STATIC value is
too high (2 digits of “1” are equivalent to approx.
1 gram).
END