BOND MANUFACTURING 66599 Owner'S Manual Download Page 10

TROUBLESHOOTING   

PROBLEM 

CAUSE 

CORRECTIVE ACTION 

Appliance won't 

light 

Igniter pin and burner are wet Wipe dry with a cloth 

Igniter battery is incorrectly 

inserted. 

Check that battery is correctly inserted.  

Igniter pin cracked or broken  Call customer service for replacement 

part 

Electrode wire is loose or 

disconnected 

 

Reconnect wire to the igniter 

box located inside the table 

base behind the igniter button 

Electrode wire is shorting 

between valve and igniter pin 

Call customer service for replacement 

part 

Burner will not 

light using a 

match 

No gas flow 

Check if gas cylinder is empty. If yes, 

replace. 

Regulator is not fully 

connected to the tank 

Check LP tank connection. 

Gas flow is obstructed 

Check hose for bends or kinks 

Spider webs or insect nest in 

the venturi (end of burner 

tube) 

Clean the venturi 

Burner ports are clogged 

Insert an opened paperclip into each of 

the burner ports to clean them. Ensure 

the appliance is off and all parts are 

cooled before attempting to clean the 

burner ports 

Appliance emits 

a lot of black 

smoke when lit 

Flame is obstructed at burner 

ports 

Make sure all the gas burner ports are 

free of any lava rocks or debris to allow 

the gas to flow freely. 

Regulator hose is pinched 

Check the regulator hose for bends or 

kinks 

Sudden drop in 

gas flow 

No gas flow 

Check if gas cylinder is empty. If yes, 

replace. 

Excess flow safety valve has 

been activated 

Turn the control knob to "OFF".  Close 

the LP tank valve and disconnect the 

regulator from the tank. Turn the control 

knob to "HIGH". Wait 1 minute. Turn the 

control knob to "OFF". Reconnect 

regulator to LP tank. Open tank valve 

slowly. Light appliance as indicated in 

"To Light" section. 

Flame blow out 

High or gusting winds 

Increase flame to "HIGH" 

No gas flow 

Check if gas cylinder is empty. If yes, 

replace. 

Excess flow safety valve has 

been activated 

See "Sudden drop in gas flow" above 

10

Summary of Contents for 66599

Page 1: ...the owner s manual thoroughly before installing or servicing this equipment If the information in this manual is not followed exactly a fire or explosion may result causing property damage personal in...

Page 2: ...as from the propane gas tank 1 Disconnect propane gas tank 2 Do not attempt to correct the problem yourself 3 Get to your gas supplier and or the fire department for help Do not operate the firebowl i...

Page 3: ...arge valve orifices or burner ports when cleaning the valve or burner Do not use this firebowl on vehicles or boats Always operate the appliance on flat ground outdoors Remove the PVC cover from the f...

Page 4: ...tion device OPD and a QCCI or Type I CGA810 LP gas tank connection Caution Only use the pressure regulator and hose assembly supplied with this firebowl Replacement pressure regulator and hose assembl...

Page 5: ...ce for the first 20 minutes Warranty and Installation Information The Bond warranty will be voided by and Bond disclaims any responsibility for the following actions Modification of the firebowl and o...

Page 6: ...ebowl on the top of the burner Do not cover the screen See Figure III 4 Open the door and put the gas tank in the metal stand Make sure the gas tank sits on the metal stand completely Turn the wing sc...

Page 7: ...is in the OFF position before disconnecting the gas supply To Disconnect Hold the regulator with the one hand and loosen the black coupling nut by turning it counter clockwise with the other hand IMP...

Page 8: ...r control knob and make sure it is in the OFF position 2 Connect propane LP cylinder See above pages 3 Open LP tank valve slowly 4 Push in igniter button to create sparks at the electrode and hold 5 P...

Page 9: ...tank to close the gas supply when not in use 4 Make sure that the unit is completely cooled before touching any of the components or putting on the cover ROUTINE CARE Keep your appliance free and clea...

Page 10: ...ged Insert an opened paperclip into each of the burner ports to clean them Ensure the appliance is off and all parts are cooled before attempting to clean the burner ports Appliance emits a lot of bla...

Page 11: ...t light using a match above IF YOU HAVE QUESTIONS OR CONCERNS PLEASE CALL BOND TOLL FREE 1 866 771 BOND 2663 OR TO BETTER EXPEDITE YOUR REQUEST FEEL FREE TO EMAIL US customer service bondmfg com OR VI...

Page 12: ...piedad Lea atentamente el manual del usuario antes de instalar o dar servicio a este aparato El no seguir exactamente las instrucciones de este manual puede producir un incendio o una explosi n con da...

Page 13: ...cm de profundidad Si aplica demasiado producto se puede acumular gas sin quemar en la chimenea para exteriores Se necesita ventilaci n para permitir que entre aire fresco en el espacio cerrado y que...

Page 14: ...menea para exteriores si alguna de sus piezas estuvo sumergida en agua No vierta agua en la chimenea para exteriores Llame de inmediato a un t cnico en mantenimiento calificado a fin de que inspeccion...

Page 15: ...o Mantenga la manguera fuera de reas donde las personas puedan tropezarse con esta o de reas donde la manguera pueda estar sujeta a da os accidentales Tanto ni os como adultos deben estar informados s...

Page 16: ...a exteriores durante los primeros 20 minutos despu s del encendido Garant a y Informaci n sobre la Instalaci n La garant a de Bond se anular por Bond y Bond declina toda responsabilidad por los actos...

Page 17: ...se Figura III 11 Abrir la puerta y ponga la bombona de gas en la base de metal Aseg rese que la bombona de gas est completamente encima de la base de metal Gire el tornillo de mariposa en la parte ext...

Page 18: ...a est en la posici n OFF antes de desconectar el suministro de gas Para Desconectar 4 Mantenga el regulador en una mano y afloje el cuello de conexi n gir ndolo en el sentido con trario a las agujas d...

Page 19: ...ue est en la posici n OFF 2 Conecte la bombona de propano LP v ase las p ginas arriba 3 Abra lentamente la v lvula de la bombona de gas LP 4 Oprima el bot n de encendido para crear chispas al electrod...

Page 20: ...la llama ajustando el bot n de control del quemador entre las posiciones LOW y HIGH 8 Siempre revise peri dicamente la llama del quemador para asegurar el buen funcionamiento Las llamas deben estar m...

Page 21: ...ebe que la pila est colocada correctamente El perno de encendido est agrietado o roto Llame al servicio al cliente para obtener una pieza de repuesto Un cable de electrodo est suelto o desconectado Vu...

Page 22: ...a conectar el regulador a la bombona de gas LP Abre lentamente la v lvula de la bombona Encienda el aparato como indicado en la secci n Para Encender La llama se apaga Vientos fuertes o racheados Aume...

Reviews: