background image

Multi-Appliance Slimline Control 

 

 

 

Bonaire Control Systems

 

Page 20

Ducted Evaporative Air Conditioning 

DUCTED EVAPORATIVE AIR CONDITIONER MAINTENANCE 

G

ENERAL

 

All  Ducted  Evaporative  Air  Conditioners  require  some  general  maintenance  to  ensure  continued  cooling 
efficiency and a long life. Maintenance is carried out at the beginning and end of summer to start up and 
close down your unit. 

We  recommend  that  all  maintenance  work  be  undertaken  by  our  fully  trained  and  accredited  Service 
Technicians or an authorised Climate Technologies Service Provider. 

The frequency of general maintenance will depend on local operating conditions such as water quality, air 
borne dust and pollen. 

It is essential that your evaporative air conditioner is maintained in accordance with this manual.  Failure to 
do so will affect the life of the product, reduce the level of efficiency and may void warranty. 

For service Australia wide refer to the details on the service section of this manual. 

NOTE:   

The manufacturer and its agents reserve the right to refuse service unless safety and accessibility 
to the unit can be guaranteed. The cost of any extra equipment required to provide access to the 
unit for servicing is the responsibility of the owner.

 

SAFETY: 

Prior to commencing any maintenance isolate the unit at the power source. Ensure the 

roof  is  safe  to  access,  your  ladder  is  securely  positioned  and  use  suitable  safety 
equipment.

 

F

ILTER 

P

ADS

 

Visually check CELDEK pads for damage or blockage.  Hose down pads from both sides to remove any 
build up of salts, dust and pollen.  In dusty areas more regular cleaning is recommended.  Check the water 
distributor,  making  sure  it  is  clear  and  free  from  blockage.    Failure  to  do  so  may  lead  to  uneven  water 
distribution and therefore less efficient operation. 

W

ATER 

T

ANK

 

It is important to keep the water tank clean and free from sediment and algae growth.  To clean the tank, 
use a soft brush or similar.  Wipe all surfaces in the tank while it is full of water (DO NOT FORGET THE 
PUMP STRAINER).  Turn off the water inlet to the unit (an Isolation Valve should be fitted to the water inlet 
before the Float Valve).  Drain the tank. It may be necessary to repeat this procedure if the tank is very 
dirty. 

SAFETY:  

Wet roofs are dangerous – Take Care When Draining Tank

W

ATER 

L

EVEL 

/

 

F

LOAT 

V

ALVE

 

The  water  level  should  be  set  at  nominal  65-70mm  before  filter  pads  are  saturated.    After  run  off  from 
operating filters the level should be 25 – 30mm from the top of the Aquamiser overflow.  The float valve is 
a mechanical type and is factory set.  If the valve is leaking, the seal may require cleaning or replacing. 
Turn of the water. Remove the split pin and then float arm.  Remove piston and clean or turn seal.  Flush 
system and replace piston, float arm and split pin. 

NOTE: 

Water supply line to float valve must be flushed before connecting.

 

 

 

Summary of Contents for Slimline

Page 1: ...appliance Slimline Control Owner s Manual Please keep this important manual in a safe place It is the owner s responsibility to ensure that regular maintenance is carried out on this ducted heating cooling product Failure to do so will void all guarantees beyond statutory and legal requirements www bonaire com au ...

Page 2: ...MOVING ERROR 9 QUICK START SIMPLE SLIMLINE OPERATION 9 Ducted Gas Central Heating 10 SAFETY 11 Safety Owner Responsibility 11 Precautions 11 Features 11 Power or Gas interruption 11 OPERATING THE SLIMLINE CONTROLLER 12 Heat Mode 12 Fan Mode 13 Auto Cool Mode Heater Evaporative Cooler 13 Manual Cool Mode Heater Evaporative Cooler 13 HEATER MAINTENANCE 14 General Customer Maintenance 14 General Main...

Page 3: ... MANAGEMENT 19 Dialflo 19 Aquamiser 19 DUCTED EVAPORATIVE AIR CONDITIONER MAINTENANCE 20 General 20 Filter Pads 20 Water Tank 20 Water Level Float Valve 20 Motor and Fan 21 Electrical 21 Bleed Off 21 Pump 21 Water Distribution 21 No Seasonal Maintenance 21 TROUBLE SHOOTING GUIDE 22 Warranty 23 SERVICE 27 ...

Page 4: ...R This technologically advanced controller comes with Slimline control for cooling and heating plus many other setup functions Your Slimline Controller has been designed to operate the following products Heating BONAIRE MB 3 4 5 Star Ducted Gas Central Heaters Fresh Air Conditioners BONAIRE Ducted Evaporative Air Conditioners ...

Page 5: ...the end of the heater or inside the cooler in the vicinity of the electronic controls These details should also be in the warranty section of this booklet You will need this information should your appliance require servicing spare parts or just if you require additional information about this product WARRANTY Warranty service work must only be carried out by Climate Technologies service division ...

Page 6: ...e with other Climate Technology products in accordance with the control system specification R W Connection This connection provides a 2 wire screw terminal for power R and the Heat output W connection The Slimline Controller will obtain power from these connections IMPORTANT These connections are only to be used if connecting to a Heater in two wire mode This connection must not be used if the di...

Page 7: ...de Fan LED indicates fan mode Cool LED indicates cooling mode 4 5 Soft Touch Buttons The following explains the function of each button ON OFF Press the ON OFF button to turn the Heating Cooling unit ON or OFF The ON OFF LED is on in the On state and off in the Off state MODE The Mode button will allow you to operate different modes of operation Each press of the Mode button cycles through the ava...

Page 8: ...on for 2 seconds will result in the set temperature changing rapidly You can set the temperature between 10 and 35 C NOTE Your heating appliance is designed to operate to 20 or 21 C Each degree above this set level will result in a significant increase in energy consumption and running costs Auto Cool Mode Auto Cool Mode can be operated if an Evaporative Cooler is connected in conjunction with a c...

Page 9: ...he error Press and hold the UP DOWN buttons for 5 seconds This will send the reset command to the appliance QUICK START SIMPLE SLIMLINE OPERATION Here s all you have to do to get going if the installer hasn t already done it for you Your Slimline Controller is designed to give you simple operation control over your product Any changes made to the control settings will have a 3 second delay before ...

Page 10: ...Owner s Operation and Maintenance Manual Please keep this important manual in a safe place It is the owner s responsibility to ensure that regular maintenance is carried out on this Ducted Gas Central Heater Failure to do so will void all guarantees beyond statutory and legal requirements www climatetechnologies com au ...

Page 11: ...ranteed The cost of any extra equipment required to provide access to the unit for servicing is the responsibility of the owner This appliance is not intended for use by young children or infirm persons unless they have been adequately supervised by a responsible person to ensure that they can use the appliance safely Young children should be supervised to ensure that they do not play with the app...

Page 12: ...OTE The controller measures the room temperature using a thermostat inside its housing When the ROOM TEMP is cooler than the SET TEMP the heater will come on after approximately a 30 second ignition process The controller will run the heater until it measures temperature a little above your SET TEMP The unit will turn off until the temperature falls a little below SET TEMP before restarting STEP 4...

Page 13: ...decrease the level of the fan speed 1 low to 12 high AUTO COOL MODE HEATER EVAPORATIVE COOLER Auto Cool Mode can be operated if the Evaporative Cooler is connected in conjunction with a central heater To operate the Auto Cool Mode STEP 1 Turn the Slimline Controller ON by pressing the ON OFF button STEP 2 Press the MODE button until AUTO appears on the display and the Cool LED turns on STEP 3 Pres...

Page 14: ...ired to the electrical system A Licensed Electrician only should carry out electrical connections and maintenance Flue The flue and cowl assembly should be clean and free of obstructions SCHEDULED MAINTENANCE NOTE It is essential that your central heater be maintained in accordance with Climate Technologies requirements Failure to do so will affect the life of the product and reduce the level of e...

Page 15: ...r run the unit No Check the unit is turned on at the power point and the gas cock is turned on Call the installer to commission the unit Yes Turn the control off then on to reset unit If the unit still does not start call for service 4 Is the SET TEMP greater that the ROOM TEMP No Increase the SET TEMP so the thermostat calls for heat Yes Reset the unit This can be done by Turn the control OFF the...

Page 16: ...onditioning Owners Operating and Maintenance Please keep this important manual in a safe place It is the owner s responsibility to ensure that regular maintenance is carried out on this Evaporative Air Conditioner Failure to do so will void all guarantees beyond statutory and legal requirements www climatetechnologies com au ...

Page 17: ...ads to provided cool fresh air The air is relieved taking with it any heat loading on the home EXHAUST It is essential for successful operation of evaporative air conditioning that there to be sufficient relief openings in the area to be ventilated Open doors and windows will usually provide this The minimum relief opening should be as per the table guide set out below It is recommended that ceili...

Page 18: ...pressing the ON OFF button STEP 2 Press the MODE button until the AUTO icon appears on the display and the Cool LED turns on STEP 3 Press the Up Down button to increase or decrease the comfort level 1 Cooler to 12 Warmer MANUAL COOL MODE To operate Manual Cool Mode STEP 1 Turn the Slimline Controller ON by pressing the ON OFF button STEP 2 Press the MODE button until the MAN icon appears on the di...

Page 19: ...te may go out of adjustment It is recommended that the bleed water is plumbed away to waste in accordance with local and state plumbing requirements Setting the Water Distribution Flow Rate To set the water distribution flow rate to the filter pads rotate filter knob anti clockwise for more water and clockwise for less water To control bleed off rate rotate bleed dial clockwise for more water and ...

Page 20: ...e the roof is safe to access your ladder is securely positioned and use suitable safety equipment FILTER PADS Visually check CELDEK pads for damage or blockage Hose down pads from both sides to remove any build up of salts dust and pollen In dusty areas more regular cleaning is recommended Check the water distributor making sure it is clear and free from blockage Failure to do so may lead to uneve...

Page 21: ...onditioner White deposits indicate high mineral content and the Bleed Rate should be increased If it is at maximum and the deposits are still forming then more regular maintenance is required PUMP Check the pump spins freely and that the strainer is clean WATER DISTRIBUTION Check the water distribution system for blockage Check the delivery tube for kinks or holes Check that the clamps are secure ...

Page 22: ... necessary Water Droplets in air stream c Pump Delivers Excessive Water to Pads c Adjust the Dialflo to reduce the flow a Inadequate Relief a Provide more open area to relieve stale air Excessive humidity b Outside humidity high b Turn pump off a Dirty Filters a Clean Replace b Dry Filters b Check water delivery system Adjust if necessary Inadequate Cooling c Dialflo not set correctly c Adjust Dia...

Page 23: ...rvice will be provided Traveling time and mileage are included within 30km of either your authorised Climate Technologies dealer or service provider s premises Customers in areas other than the above are responsible for any traveling time and mileage required to carry out warranty repairs The product must be installed by a qualified person in the manner prescribed by local statutory regulations an...

Page 24: ...ble Conditions where warranty may be void If there is no certificate of compliance for plumbing electrical or refrigeration as required by State Territory Laws Climate Technologies reserves the right to refuse service on non compliant installations The defective operation of the appliance that is due to failure of electricity gas water or refrigerant gas supplied Defects are caused by neglect inco...

Page 25: ... filter s and zone motors are field supplied and therefore are not covered by the above warranty periods Ducted Evaporative Air Conditioning Domestic RESIDENTIAL COMMERCIAL Unit Components Parts Labour Parts Labour Corrosion on Cabinet 25 3 2 2 Structural Guarantee 10 3 2 2 All other components 3 3 1 1 Filter pads are a consumable and are therefore not covered by this warranty WARRANTY ON REPLACEM...

Page 26: ...the operation of this product The Dealer or retailer is also responsible for issuing the relevant certificates of compliance for the electrical connections These may differ from state to state Please attach your proof of purchase here Your receipt is your warranty and will be required to validate any warranty DEALER PRODUCT INFORMATION Dealer Retailer Dealer Address Dealer Phone Number Unit Model ...

Page 27: ...ve the efficiency benefits the product provides For Metro Service only ring the numbers below South Australia 1300 665 087 Email saservice climtech com au New South Wales 1300 665 087 Email nswservice climtech com au Queensland Australian Capital Territory 1300 665 087 Western Australia 1300 665 087 Email waservice climtech com au Victoria Tasmania 03 8795 2456 Email vicservice climtech com au Mob...

Page 28: ...5442281C Manufactured by Climate Technologies ABN 13 001 418 042 26 Nylex Avenue Salisbury SA 5108 Australia www bonaire com au ...

Reviews: