Bonaire Window Cooler
Installation
8
Page
External Fixing of the Unit
Ensure that the location chosen to mount the cooler is strong enough to support the operating weight
of the unit. The
operating weight is 84 lbs (38 kg).
Ensure that the window opening is large enough for the duct of the cooler. Nominally
(560mm)
high by
(381 mm) wide.
Ensure there is a minimum (100mm) clearance above the external cabinet for maintenance
purposes.
Position the cooler through the window (two or more people will be required for this) so that the unit
is hard up against the outside wall of the house.
Note that if the cooler does not fit hard up
against the outside wall (e.g. a protruding
timber or brick window sill), utilize a spacer
block of wood (not provided), which must be
attached to the wall.
Ensure that the unit is installed level in the vertical and horizontal positions as illustrated, prior to
fixing the cooler.
Alternative option
Instead Metal Angle Brackets
Wooden Stand for Swamp cooler
can be used (not included)
For solid walls, brick or masonry, use suitable masonry lag anchors.
Place the unit in position, mark screw positions, remove unit then drill pilot holes for timber walls
or 3.2mm).
Replace unit in window, fit screws with Washers 3/16 x 7/16 x 20g flat
Metal Angle
Brackets