PROBLEM
PROBABLE CAUSE
REMEDY
Unit fails to start
a
b
c
d
e
Power Failure
Tripped Circuit Breaker
Blown Fuse
Electrical Fault
Motor failure
a Wait for power to be turned on.
b Reset circuit breaker
c Replace
d Call Bonaire Care Line
e Change the motor
Filter Pads not
wetting.
a Pump Seized
b No water restrictor
c Electrical fault with pump
d Needs smaller restrictor
e High voltage in your area
a
b
c
Extension cord dropping voltage
Maintenance page. See Pump section.
Call Bonaire Care Line
Filter pads too wet
Water leaking from
overflow
a
b
Float Valve Leaking
Drain from Filter Pads
a
b
Check adjustment or replace float valve
if necessary
Normal Operation adjust float level
Water Droplets in
air stream
a
b
c
Loose Delivery Tube
Break in tubing
Pump appears to deliver
excessive water to pads
a Check and tighten
b Replace as necessary
c. Check the condition of the filter pad.
Wash if pad shows heavy buildup of
minerals
Excessive humidity
a
b
Not enough air flow
Inadequate Exhaust
a
b
Increase fan speed
Provide more open area to exhaust
stale air by opening windows and doors
in adjacent rooms.
Inadequate
Cooling
a
b
Dirty Filters
Dry Filters
a
b
Clean
Check control set on COOL mode.
Check water delivery system. Adjust if
necessary.
Unpleasant Odor
a Unit located near odor source
b Algae in water tank
a
b
Remove source
Clean tank and refill with fresh water.
ANY FURTHER PROBLEMS PLEASE CONTACT YOUR
BONAIRE CUSTOMER CARE LINE ON 1-800-939-2983
Problem Solving