Maintenance

Set 

the correct 

room

 

temperature

Close doors and windows
during operation

If the unit is not to be used

 

for  a  long 

period

,  turn  off 

the

 

power  supply  main

 

switch.

Use the timer effectively

Use the louvers effectively

Do not block the air inlet

 

or outlet

Proper

temperature

During cooling operation

prevent the penetration 
  of direct sunlight with

curtain or blind

OFF

Remote Controller

Indoor Body

3.Attach 

an 

Air Purifying Filter

Put air purifying filter appliances into the

right and left filter frames.

NOTE:

1.

Open the lnlet Grille

Prop up the inlet grille by using a
small device named grille-support
which 

is 

located in the right side of

the indoor unit.

2.

Detach the standard air filter

Slide the knob slightly upward to
release the filter, then withdraw it.

During the course of normal domestic use, the 
photocatalyst

 

air purifying filter

 

will require recharging. This 

can be done by simply exposing the filter to direct sunlight 
every 6 months.
The bacteria-killing medium air purifying filter

 

will be used 

for a long time

 and does not require 

replacement. But in the 

period of using them ,you should remove the dust frequently 
by using 

vacuum cleaner or 

dusting

 them lightly,otherwise,

its performance will be affected. 

Please keep the bacteria-killing medium air purifying filter in

 

cool and dry conditions

 and 

avoid

 

long

 terms 

sun

 exposure 

when

 

you

 

stop

 

using

 

it,

 

or

 

its

 

ability

 

of sterilization

 

will

 

be

 

reduced.

For 

best

 

u

se of

 your A

ir Conditioner

Replacement of Air Purifying Filter

4.

Attach the standard air filter

(Necessary installation)

ATTENTION:

The white side of the 

photo catalyst

 air purifying filter

fac

es

 outside,

 

and the black side face

s

 the unit

The

green

 

side

s

 of the bacteria-killing medium air purifying

filter face

 

outside,

 

and the white side face

s

 the unit.

5.

Close the Inlet Grille

 

firmly

Do not use

 

water,wipe the 

controller

 

with a dry cloth.

 

Do not 

use glass

 

cleaner or chemical cloth.

W

ipe the air conditioner by using a 

soft and dry cloth.

 

For 

stubborn

 

stains,

 

use a neutral detergent 

diluted with

 

water.

 

Wring the water 

out of the cloth before wiping,then 
wipe off the detergent completely.

Air Filter cleaning

Open the inlet grille by pulling it upward.

Remove the filter.

Clean the filter.

Attach the filter.

Close the inlet grille.

Push up the filter's center tab slightly until it is 

from the stopper, and remove the filter downward.

Use a vacuum cleaner to remove dust, or  wash the filter with
water.After washing, dry the filter completely in the shade.

Attach the filter correctly so that the "FRONT" indication

facing to the front.Make sure that the filter is 

fixed behind the stopper.If the right

attached correctly, that 

Do not use the following for cleaning

Gasoline,benzine, thinner or cleanser

ay damage the coating of the unit.

Hot water over 40

O

C(104

O

F) may

discoloring or deformation.

Once every
two weeks

m

cause

released

 is

completely

and left filters are not

may cause defects.

Detach old Air Purifying Filter

Summary of Contents for CRC6910025

Page 1: ......

Page 2: ......

Page 3: ...Contents PARTS AND FUNCTIONS OPERATION MAINTENANCE CAUTIONS TROUBLE SHOOTING ...

Page 4: ...COOL DRY Remote controller HEAT LO MED HI AUTO Display circulated Additional functions display 1 2 3 4 5 9 10 11 12 13 14 15 16 17 8 22 23 24 25 19 20 21 18 7 6 Operation mode Remote controller QUIET TURBO SLEEP Supplemented electrical heating HEALTH Function SLEEP HEALTH airflow position1 HEALTH airflow position 2 Power Air sending A B yard Display board A Display board B Display board C Display ...

Page 5: ...ated temperature Timer mode Fan speed Operation mode Above 23 o C Below 23 o C 23 o C 26 o C No AUTO AUTO COOL HEAT No These modes cannot be changed and is intended for testing or in the case of losing the remote control Test operation Test operation switch is the same as emergency switch LOW MED HI AUTO 1 Unit start Press ON OFF on the remote controller unit starts 2 Select operation mode COOL bu...

Page 6: ... POWER Mode If power mode is activated the unit will run on HIGHEST power to provide rapid cooling heating To activate press button to enter additional options Press repeatedly until flashes then press to enter into POWER mode To cancel this function enter EXTRA FUNCTION again and press CANCEL when the arrow symbol is displayed 2 QUIET Mode This mode will run the unit on it s LOWEST power to produ...

Page 7: ...use condensate water to occur at the grille 2 In heating it is better to select the 3 In cooling it is better to select the mode mode TIMER OFF ON 0 5h 0 5h 0 5h 0 5h Press the button for each time setting time in the first 12 hours increases by 0 5 hour every time after 12 hours it increases by 1 hour Press the button for each time setting time in the first 12 hours decreased by 0 5 hour after 12...

Page 8: ...ing it or its ability of sterilization will be reduced For best use of your Air Conditioner Replacement of Air Purifying Filter 4 Attach the standard air filter Necessary installation ATTENTION The white side of the photo catalyst air purifying filter faces outside and the black side faces the unit The green sides of the bacteria killing medium air purifying filter face outside and the white side ...

Page 9: ...ce where there is any STRICT ENFORCEMENT STRICT STRICT ENFORCEMENT PROHIBITED PROHIBITED PROHIBITED PROHIBITED Do not start or stop the operation by disconnecting Do not channel the air flow directly at people especially at infants or the aged Do not try to repair or reconstruct by yourself Do not use for the purpose of storage of food art work precise equipment breeding or cultivation CAUTION Ven...

Page 10: ... a big noise from air flow in unit operation the air filter may require cleaning will work for 3 minutes to protect the air conditioner immediately until 3 minutes have Cautions Notes 2 If the power supply cord is damaged it must be replaced manufacturer qualified person or its service agent or a similar 3 The appliance must be installed by a qualified installer 4 After installation the power plug...

Page 11: ...INTENTIONALLY LEFT BLANK ...

Page 12: ... Ltd June 2019 All rights reserved The product specifications in this booklet apply to the specific products and models described at the date of issue Under our policy of continuous product improvement these specifications may change at any time You should therefore check with your dealer to ensure this booklet correctly describes the product currently available ...

Reviews: