Storage
It is advisable to store the machine in its original packaging. Doing so makes it possible to form a column of two
packages maximum, with one on top of the other.
If the machine is removed from the original packaging and is not used for some time ensure the wheels and drum
are not in contact with the ground. In this case use two supports at least 50mm in height to rest the machine on,
ensuring contact is with the base frame.
ATTENTION
This equipment is for dry use only and must not be used or kept outside in wet conditions. Store the machine
in a dry building, otherwise the machine could be damaged.
Storage temperature from -20°C to 50°C.
Transporting and handling the machine
Transport with one person
WARNING
Request assistance to lift the machine due to its heavy weight.
The machine can be dismantled into two parts to facilitate transportation:
- the suction tube and handle unit
- base frame with drum and motor
Proceed as follows:
1.
Ensure the power supply
cable is disconnected from
the mains and the machine.
2.
After moving the lever forwards (
pos. 1 fig. A
) lift the tube (
pos. 3
) and release
the bar (
pos. 4
) from the cylinder (
pos. 2
).
3.
Remove the plug (
pos. 6
) from the socket
(
pos. 7
) by turning the plug anti-clockwise.
4.
Loosen the handle (
pos. 5 fig. A
) and remove the
tube from its housing and bring it to the place of work.
5.
Lift the base frame by clasping the hub of the belt guard on the upper part (
pos. 1 fig. B
) and the base frame
itself on the lower part.