14 

 

 

EU Product Data Sheet 

Product information for household tumble dryer according to regulation (EU) No. 392/2012 

Brand 

 

BOMANN 

Model 

 

WPT 5021 

Rated capacity 

kg 

Dryer type 

 

Condenser 

Energy efficiency class

1)

 

 

A++ 

Annual energy consumption

2)

 

kWh/a 

235.3 

Automatic tumble dryer 

 

∙ 

Energy consumption standard program 

 

 

- with full load 

kWh 

1.98 

- with partial load 

kWh 

1.08 

Power consumption: off mode 

0.01 

Power consumption: left-on mode 

0.8 

Duration of the left-on mode 

Min. 

10 

Standard programm

3)

 

 

Cotton Standard 

Program time of standard cotton program 

 

 

- weighted at full and partial load 

Min. 

149 

- average at full load 

Min. 

195 

- average at partial load 

Min. 

115 

Condensation efficiency class

4)

 

 

Condensation efficiency class standard program 

 

 

- average at full load 

81 

- average as partial load 

81 

- weighted at full and partial load 

81 

Noise level 

dB(A) 

69 

Built-in appliance 

 

 

1)

 

A+++ (highest efficiency) to D (lowest efficiency). 

2)

 

Weighted annual energy consumption based on 160 drying cycles for the standard program with a full load and partial load, as well as the consumption of 
operating modes with lower power consumption. The energy consumption per cycle depends on the type of use of the appliance. 

3)

 

The “Cotton standard” program with a full load and a partial load is the standard drying program on which the information on the label and in the datasheet 
is based. This program is suitable for drying normal wet cotton fabrics and is the most efficient regarding the energy consumption for cotton. 

4)

 

A (highest efficiency) to G (lowest efficiency). 

 
 
 
 
 
 

Summary of Contents for WPT 5021

Page 1: ...HOUSEHOLD HEAT PUMP DRYER WPT 5021 Instruction Manual...

Page 2: ...y Information for this Unit Page 4 Transport and Packaging Page 5 Appliance Equipment Page 6 Installation Page 6 Startup Operation Page 7 Cleaning and Maintenance Page 11 Troubleshooting Page 12 Techn...

Page 3: ...ng instructions may differ from the original device The appliance is designed exclusively for private use and for the envisaged purpose This appli ance is not fit for commercial use The appliance is o...

Page 4: ...enings in the appliance base if existing may not be clogged blocked e g by carpet Do not place the appliance behind a lockable door a sliding door or a door with a hinge that lies opposite the door hi...

Page 5: ...sal of the appliance Precautions for refrigerant loss WARNING The refrigerant circuit of the heat pump contains a non toxic odorless refrigerant R134a that volatilizes rapidly upon release It is heavi...

Page 6: ...et must be freely accessible Good ventilation around the appliance is required in order to dissipate the heat properly Enough clearance must be created for this purpose The free space in front of the...

Page 7: ...ppliance back before connecting Connect the mains cable to a properly installed and earthed wall outlet If the plug after installation is not accessible a corresponding disconnect device must be avail...

Page 8: ...especially smooth Do not overload the appliance Each load should correspond to the rated capacity of the appliance Ensure that no items of washing are trapped in the door Close the appliance door Mak...

Page 9: ...g 10 LED Display Display for settings and information The start delay and the drying time are selected via the display The remaining running time of the start delay DELAY is displayed the program is s...

Page 10: ...e electronic control guarantees the best drying results even with low loading of the dryer It is enabled for all programs except for the pro grams with time control Capacity Do not overload the applia...

Page 11: ...ergy consumption Ventilate the room well The room temperature should not rise above 35 C Cleaning and Maintenance WARNING Always switch off the appliance and disconnect it from the power supply before...

Page 12: ...ion tank press the START PAUSE button to continue the drying pro cess Troubleshooting Before you contact an authorized specialist For some malfunctions the display shows error codes to warn you Troubl...

Page 13: ...waste Please return any electrical equipment that you will no longer use to the collection points provided for their disposal This helps avoid the potential effects of incorrect disposal on the enviro...

Page 14: ...ficiency class4 B Condensation efficiency class standard program average at full load 81 average as partial load 81 weighted at full and partial load 81 Noise level dB A 69 Built in appliance 1 A high...

Page 15: ...15...

Page 16: ...16 C Bomann GmbH www bomann germany de Made in P R C Stand 04 2020...

Reviews: