19
•
Remove for that the appliance content and stor-
age at a cool location.
•
Clean the thaw water discharge channel / opening
carefully e.g. with a pipe cleaner.
•
After everything was thoroughly dried, you can
restart the operation.
Defrosting
The appliance has an automatic defrosting system.
During defrosting water drops drains off at the back
of the cooling chamber. The thaw water running
through a channel, is collected in a drip tray located
on the compressor, where it will evaporate. Make
sure the water discharge opening does not get
clogged. A light formation of ice on the interior back
during operation is normal.
Changing the bulb
Lamp specifications: 220-240 V
~ / max.
10 W
•
Remove the lamp cover carefully.
•
Change the bulb.
•
Reattach the lamp cover properly.
Troubleshooting
Before you contact an authorized specialist
Problem
Cause / Action
Appliance is
not working
properly or
at all
-
Check the power supply / temperature
setting / ambient temperature.
-
Unblock the ventilation openings, install
the appliance freely.
Stored food
is too warm
-
Check the temperature setting / ambi-
ent temperature.
-
Open the door only as long as neces-
sary.
Loud noise
during oper-
ation
-
Check the appliance position.
-
See the section “Operating noise”.
Water on the
appliance
bottom
Check the temperature setting /
water
discharge channel or opening.
Problem
Cause / Action
Light does
not work
-
Check the power supply.
-
See “Changing the bulb”.
NOTE:
If a problem still persists after following the steps
above, contact your trader or an authorized techni-
cian.
Technical Data
Electrical connection………………...…………………..
Power voltage: ………………......….220-240 V~ / 50 Hz
Connection power: ……………………….…..….…..70 W
Dimension H x W x D / Weight…..…...………………..
Appliance size: ……..….…....….…84.5 x 55.0 x 56.8 cm
Net weight: …………………………..……approx. 27.0 kg
The right to make technical and design modifications
in the course of continuous product development
remains reserved.
This appliance has been tested according to all rele-
vant current CE guidelines, such as electromagnetic
compatibility and low voltage directives, and has
been constructed in accordance with the latest safety
regulations.