ADDRESSABLE FIRE ALARM SOUNDER
S2000-OPZ
INSTRUCTION MANUAL
1
TECHNICAL INFORMATION
1.1
General
S2000-OPZ Addressable Fire Alarm Sounder (hereinafter referred to as OPZ) is designed to emit fire and emergency sound signals in various facilities as well as
to issue sound signals when the OPZ is used as a part of intrusion alarm systems within heated premises. OPZ is used with a polling loop controller S2000-KDL or
S2000-KDL-2I (hereinafter referred to as PL controller) within an Orion integrated security system. Electric power is supplied and data of the addressable part of the
OPZ are communicated via the polling loop (PL) of the PL controller. The OPZ supports the polling loop protocol DPLS_v2.xx and provides measuring of the
addressable loop voltage at the point where it is connected. OPZ is equipped with a tamper switch. The audible announcement circuit is galvanically isolated from the
addressable part of the OPZ and thus from the polling loop and provides connecting one or two external power supplies with monitoring their output voltage.
The version of OPZ firmware is v.1.00.
The OPZ is designed for round-the-clock operation and relates to reparable and periodically serviced products.
1.2
Specifications
1.3
Standard Delivery
1)
Input Polling Loop Voltage
-
8 to 11 V
For an individual delivery:
2)
Current Consumed From the Polling Loop
-
0.6 mA max
–
S2000-OPZ Sounder
-
1 pc.;
3)
Start-up Time
-
15 s max
–
Instruction Manual
-
1 pc.;
4)
External Power Voltage
-
10 to 28.5 V
–
4.2
х
38 DIN7981 Tapping Screw
-
2 pcs.;
5)
Current Consumed from External Power Supply
-
60 to 20 mA
–
Wall Plugs 6
х
30
-
2 pcs.;
While powering from a 12 V dc power supply
-
45 mA
–
Packing
-
1 pc.
While powering from a 24 V dc power supply
-
23 mA
6)
Maximum galvanic insulation voltage
-
500 V max
7)
Sound Pressure Level at 1m (in front of the sounder)
-
97 dB min
8)
Ingress Protection Rating
-
IP41
9)
Operating Temperature
-
Minus 20 to +55
°
C
10)
Relative Humidity
-
Up to 93% at +40°C
11)
Transportation and Storage Temperature
-
Minus 50 to +55
°
C
12)
Overall Dimensions
-
160
×
115
×
48 mm max
13)
Weight
-
0.35 kg max
14)
The content of precious material: does not require accounting for storage, retirement, and
disposal.
2
OPERATION INSTRUCTIONS
2.1
Connection Diagram
Figure 1 shows the schematic for connecting the OPZ to a polling loop controller.
Figure 1
2.2
Mounting the OPZ
The OPZ is to be mounted on a wall with the help of two or three woodscrews in accordance with the requirements of construction rules and regulations.
The OPZ should be attached to the wall as shown in Figure 2 with the printed circuit board (specified in dotted line) on the top.
Figure 3 represents the coverage pattern of the OPZ (top view) mounted on the wall as shown in Figure 2. The cross sign in Figure 2 is the center relatively
which the values of sound pressure levels in the coverage pattern are specified.
Figure 2
Figure 3
S2000-OPZ
RIP-12 (24)
Secondary Power Supply
4
−
PL
3
2
1
+PL
−
PL
+PL
1
+ U2
+ U
0 V
RIP-12 (24)
Primary Power Supply
0 V
+ U
XT2
XT1
2
3
4
– U2
+ U1
– U1
To S2000-KDL
To other addressable devices
To other addressable devices