8
Electrical wires, buttons and switches must be monitored to keep them in order. Faulty wires and compo-
nents must be replaced immediately.
4.1.1 MAINTENANCE AND INSPECTION DURING OPERATION
Daily inspection and inspection before each operation is needed for the following (maintenance when
needed):
A. Emergency stop -switch
Approximate examination during operation:
• check attachment of switches onto case/control panel
• check attachment of containers and covers
• loosening of mushroom shaped Emergency-switch -> replacement
• replace or clean dirty switches
• replace switch if dirt affects operation
• replace swiches if chemicals have deteriorated them or made them brittle
• replace switches if they are battered, fractured or strained
• ensure free access and easy reachability of switches
4.1.2 MAINTENANCE AND INSPECTION EVERY 12 MONTHS
Inspect and maintain the following. Checkup includes visual perception and auditional observation.
A. Case/body of Miniroller
Inspection for twists, chips and other damages. Damaged parts must be replaced.
B. Bearings
Inspection of bearings for intactness.
C. Screwed, bolted and welded connections
Inspection of all connections for adherence and inspection of fasteners. Replacement, tightening or re-
pairing if needed.
D. Condition of rotating rollers
Inspection of surface of rotating rollers. If notably worn out, it must be replaced.
E. Lubrication of electrical conductors and trapeze screw
Lubrication of linear guideways through upper holes of liner axle.
Light lubrication of trapeze screw if needed.