background image

6

®

Model SM

 Air Defrost

Model

No. 

of 

Fans

Dimensions

L

in.

mm

SM052

1

31-1/

800

SM076

2

53-1/

1359

SM090

2

53-1/

1359

SM102

3

53-1/

1359

SM108

3

75-1/

1918

SM134

3

75-1/

1918

SM156

4

75-1/

1918

SM179

4

97-1/

2477

SM208

4

97 1/

2477

SM249

5

119-1/

3035

Physical Data

Model SME

 Electric Defrost

Model

No. 

of 

Fans

Dimensions

L

in.

mm

SME040

1

31-1/

800

SME054

2

53-1/

1359

SME065

2

53-1/

1359

SME090

3

75-1/

1918

SME130

3

75-1/

1918

SME174

4

97-1/

2477

NOTE:

 All units have 1/4" OD external equalizer and 3/4" FPT drain connection

Model SM

 Air Defrost

Model

No. 

of 

Fans

Connections (in.)

Approx. Net Wt.

Inlet OD 

Suction OD 

lbs.

kg

SM052

1

1/2

7/8

19

SM076

2

1/2

7/8

6

29

SM090

2

1/2

7/8

70

32

SM102

3

1/2

7/8

83

38

SM108

3

1/2

7/8

105

48

SM134

3

1/2

7/8

117

53

SM156

4

1/2

7/8

13

56

SM179

4

1/2

7/8

19

68

SM208

4

1/2

1-1/8

16

74

SM249

5

1/2

1-1/8

06

94

Model SME

 Electric Defrost

Model

No. 

of 

Fans

Connections (in.)

Approx. Net Wt.

Inlet OD 

Suction OD 

lbs.

kg

SME040

1

1/2

7/8

90

41

SME054

2

1/2

7/8

10

54

SME065

2

1/2

7/8

10

54

SME090

3

1/2

7/8

160

73

SME130

3

1/2

7/8

17

79

SME174

4

1/2

1-1/8

18

99

Dimensional Data

3/8" DIA. MTG. HOLES

ELECTRICAL

CONNECTION 

(OPPOSITE SIDE)

REFRIGERANT

CONNECTION

(OPPOSITE SIDE)

DRAIN

AIR OUT

AIR OUT

AIR IN

REFRIGERANT
CONNECTION

REFRIGERANT
CONNECTION

AIR IN

7-9/16"

192 mm

8-5/8"

219 mm

28-13/16"

732 mm

3/5"

31 mm

3/5"

31 mm

6-7/8"

175 mm

  L

27-5/8"

702 mm

5-1/2"

140 mm

2-7/8"

71 mm

5-3/4"

146 mm

22"

560 mm

10-1/4"

261 mm

11-3/4"

299 mm

22"

560 mm

3-13/16"

97 mm

Summary of Contents for BN-CMTB

Page 1: ...center mount unit coolers Technical Guide Models SM Air Defrost SME Electric Defrost bn cmTB April 2008 Replaces BN CMTB October 2007 www thecoldstandard com...

Page 2: ...geration Parts Because they re a drop in replacement for existing shaded pole and PSC motors installation is quick and easy It s a high impact quick payback solution for reducing costs and achieving g...

Page 3: ...r slope for condensate drainage to one end of the unit Motors Motors are life lubricated and thermal overload protected EC motors optional available factory installed or as a drop in replacement throu...

Page 4: ...700 2 890 SM156 14 820 4 340 22 230 6 510 3 1 650 2 800 SM179 17 010 7 980 23 290 6 820 4 2 270 3 855 SM208 19 760 5 790 29 640 8 680 4 2 200 3 735 SM249 23 660 6 930 32 400 9 490 5 2 745 4 665 Model...

Page 5: ...1 8 110 1 0 110 SM090 1 15 1 7 160 0 8 160 1 8 110 1 0 110 SM102 1 15 2 5 240 1 2 240 1 8 110 1 0 110 SM108 1 15 2 5 240 1 2 240 2 7 165 1 5 165 SM134 1 15 2 5 240 1 2 240 2 7 165 1 5 165 SM156 1 15...

Page 6: ...052 1 1 2 7 8 42 19 SM076 2 1 2 7 8 64 29 SM090 2 1 2 7 8 70 32 SM102 3 1 2 7 8 83 38 SM108 3 1 2 7 8 105 48 SM134 3 1 2 7 8 117 53 SM156 4 1 2 7 8 123 56 SM179 4 1 2 7 8 149 68 SM208 4 1 2 1 1 8 164...

Page 7: ...de Fan Guards Part Description No Fans 5036SS Motor 115 1 60 Shaded Pole 1 5 5036TS Motor 208 230 1 60 Shaded Pole 1 5 5036NS Motor 115 1 60 50 PSC 1 5 5036PS Motor 208 230 1 60 50 PSC 1 5 25305901 Mo...

Page 8: ...FAX 770 465 5990 www thecoldstandard com For more information on Bohn refrigeration products contact your Sales Representative or visit us at www thecoldstandard com Since product improvement is a co...