background image

10

Operation

Output Limiter

The Output Limiter control sets the threshold at which the unit hard
limits the output signal. Once the Limiter's threshold is exceeded, the
output signal is prevented from increasing any further. With the control
set to the Min position (fully counterclockwise), the Limiter will pro-
vide almost no limiting and is essentially turned off. It will only engage
when very large output levels are produced. As the control is turned
clockwise, more limiter function will be allowed and the output level
necessary to engage the Limiter decreases.

Typically, the Limiter is set to prevent clipping caused by overdriving the
amplifier beyond its maximum output level. This setting is established by
using both the Output Level Meter and the Limiter LED.

First, adjust the amplifier’s output level until the Output Level Meter
registers in the amber region. Then, adjust the Output Limiter control
until the Limiter LED illuminates intermittently. The LED associated
with the Limiter illuminates when the Limiter is engaged. If the output
level of the amplifier exceeds this point, then the Limiter will engage,
thereby keeping the Output Level Meter in the amber region. The
Limiter can also be set to restrict the amplifier's output level to a
desired level below the amplifier's maximum level to provide a means
of limiting the system's volume level. In this case, the amplifier is driven
to the desired output level and then the Limiter control is adjusted so
that it begins to engage. In general, input and master controls should be
set so that the Limiter engages as little as possible.

Rear Panel Controls

Trans Output / Direct Out Selector Switch

A large slide switch next to the amplifier’s output barrier strip deter-
mines transformer-coupled or direct output operation. The setting of
this switch controls which amplifier output terminals are active and
what type of filter shape will be used for the bass control. See the

Connections

section for more information about the load selector

switch.

Other Controls 

(Located In Module Bay 6)

Tone Control Bypass Switch

A slide switch that can bypass the effects of the Bass
and Treble controls is located on the back plane of
module bay 6. It is sometimes desirable to bypass
the tone controls when other forms of system
equalization are used. A screwdriver can be used to
set the switch. The switch must be set before a
module is installed in this bay.

Lo-Cut Switch

The Power Vector Amplifier provides a lo-cut filter
that rolls off frequencies below 

1

25 Hz. The slide

switch for this function is located on the back plane
of module bay 6.  A screwdriver can be used to set
the switch. The switch must be set before a module
is installed in this bay.

Summary of Contents for WV100

Page 1: ...Wall Mount Power Vector Amplifiers WV100 WV150 WV250 Models Installation and Use Manual 2002 Bogen Communications Inc All rights reserved Specifications subject to change without notice 54 2086 01E 1204 ...

Page 2: ...n for replacement of the obsolete outlet 10 Protect the power cord from being walked on or pinched particularly at plugs convenience receptacles and the point where they exit from the apparatus 11 Only use attachments accessories specified by the manufac turer 12 Unplug this apparatus during lightning storms or when unused for long periods of time 13 Refer all servicing to qualified service person...

Page 3: ...e Speaker Connections 6 COM and GND Terminals 7 Remote Volume Control 7 Mute Control 7 Bridging Mix Bus 7 System Expansion of Power Vector Amplifiers 8 OPERATION 9 10 Front Panel Controls Indicators 9 Input Volume Controls 9 Signal Clip Indicator 9 Bass and Treble Controls 9 Master Volume Control 9 Average Peak Switch LED Output Meter 9 Power Switch Power Indicator 9 Output Limiter 10 Rear Panel C...

Page 4: ... Control determines maximum amp output level before limiting takes place Indicator illuminates when limiting takes place 5 Average Peak Switch This switch determines whether the LED Output Meter registers the average or peak level of the amplifier s output 6 LED Output Level Meter An 11 segment LED output level meter monitors the output level of the power amplifier 7 Tape Out RCA unbalanced signal...

Page 5: ...Vector Connector Board Rear 1 Trans Output Direct Out Selector Allows selection of either TRANS for transformer coupled outputs 70V 25V and 8 ohm or DIR for direct low impedance 4 ohm minimum output 2 Speaker Output Barrier Strip A terminal barrier strip with clamping washers provides connections for speaker loads 3 Mute Control Terminals Provides access to mute buses for external control and syst...

Page 6: ...talled A white screened area is provided on the front of the amplifier below the connector to identify the connector s purpose and associated input number Remove the filler cap in the upper left hand corner of the front panel and install the combination jack as shown in the figures below Either or both of the connector styles on the jack can be wired to any user supplied module with included cable...

Page 7: ...lar module bay and is not processed by the output module directly The input is includ ed so that the additional input function of the module bay is not forfeited when an output module is installed Input Modules Functionality The Wall Mount Power Vector series of amplifiers accepts Bogen s new advanced plug in input modules which provide a wide range of input types allowing the amplifier inputs to ...

Page 8: ...e 4Ω terminal and the GND terminal Make sure the selector switch is in the DIR position Bypassing the output transformer and driving the speaker load directly provides the advantage of better bass response To maximize the power delivered to the speakers their combined load impedance should be 4 ohms Connecting higher load impedances is electrically acceptable but the mismatch in load impedance wil...

Page 9: ...level of the MasterVolume control The impedance of the shorting connections must be less than 100 ohms in order to operate the control Mute Control Each priority bus High Medium and Low can be externally activated This allows priority buses of two or more Wall Mount Power Vector units to be linked together for system expansion purposes A particular mute priority can be externally forced by shortin...

Page 10: ...is not rec ommended that more than three amplifiers be bridged together due to bridging loss When connecting mute control functions make certain that the wiring is consistent H to H M to M and so forth See illustration below Note When connecting mute control functions between amplifiers make certain that the wiring is consistent H to H M to M and so forth ...

Page 11: ...ow 40 Hz This filter shape helps to avoid overdriving the speaker s coupling transformer with low frequency signals that may cause noticeable distortion due to magnetic saturation of the transformer s core Master Volume Control The overall volume level of the amplifier is set by a Master Volume control The Master Volume control is motorized and can be controlled by manually adjusting the knob or b...

Page 12: ... a desired level below the amplifier s maximum level to provide a means of limiting the system s volume level In this case the amplifier is driven to the desired output level and then the Limiter control is adjusted so that it begins to engage In general input and master controls should be set so that the Limiter engages as little as possible Rear Panel Controls Trans Output Direct Out Selector Sw...

Page 13: ...Block Diagram 11 ...

Page 14: ...mpedance Transformer Coupled 70V 25V 8 ohms balanced or unbalanced Direct Coupled 4 ohms unbalanced Thermal Emissions WV100 495 2 BTU hr WV150 696 7 BTU hr WV250 911 9 BTU hr Tape Out Output Level 4 VRMS FRP Output Impedance 50 ohms maximum Protection Thermal short circuit and overload auto reset Line Fusing Resettable circuit breaker Cooling Thermally controlled 3 speed fan Power Consumption WV10...

Page 15: ...connections Trans Out load on wrong tap Bass control boosted too much POOR LOW FREQ RESPONSE NO BASS Power Indicator LED is red Input Signal Clip LED is green LED Output Meter not in red Lo cut switch is set to ON Speakers wired out of phase Check module bass control setting if available Check bass control setting Note Transformer coupled speakers have less bass response Power Indicator LED is red...

Page 16: ... or repaired or altered in any manner whatsoever or where the serial number or date code has been removed or defaced THE FOREGOING LIMITED WARRANTY IS BOGEN S SOLE AND EXCLUSIVE WARRANTY AND THE PURCHASER S SOLE AND EXCLU SIVE REMEDY BOGEN MAKES NO OTHER WARRANTIES OF ANY KIND EITHER EXPRESS OR IMPLIED AND ALL IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DIS...

Page 17: ......

Reviews: