Bogen DFT120 Installation And Use Manual Download Page 4

4

Overview

Features and Capabilities

The Digital Feedback Terminator has 4 minutes of available audio memory and can record up to 

1

6 paging messages.

A single page can have a maximum length of 

1

minute.The unit can record new pages while playing back previously

recorded pages.
The DFT

1

20 eliminates feedback over the paging system by opening the loop between the input microphone and the

speakers.This not only eliminates the potential for acoustic feedback, but also gives the user flexibility in the manner
in which pages are broadcast.
Multiple Record and Playback options are supported, as well as Pre-Page Tones, Message Repeat, and Adjustable Delay
Between Message Repeats functions.Abort and Stop functions are also available.
The DFT

1

20 includes a transformer-isolated 600-ohm page input and priority override input, as well as a transformer-

isolated switchable 8-ohm or 600-ohm audio output.

Specifications

Physical

Maximum dimension:

1

0" W  x 

1

1

/

2

" H x 6

1

/

2

" D

Weight: 4.5 lb. (2 kg)

Electrical

Frequency Response: 6.8 kHz, and 60 dB of dynamic range

Page Audio Input: 600 ohms, transformer-isolated, with -20 dBm to +4 dBm (nominal 0 dBm) input level

Priority Audio Input: 600 ohms, transformer-isolated, with -20 dBm to +4 dBm (nominal 0 dBm) input level

Selectable Audio Output:

Line Output 

(600 ohms, transformer-isolated, +4 dBm max. continuously adjustable) or

Power Output

(8 ohms, transformer isolated, limited to approximately 0.

1

25 Watts into 8 ohms, adjustable)

Relay contacts:All control relay contacts available are rated at 

1

Amp, 24V DC noninductive loads

Power requirement:

1

2V DC,

Amp from wall-mounted power pack supplied

Memory Capacity: 240 seconds,

1

6 messages max., up to 

1

minute max. per message

Environmental

Capable of operating in ambient temperatures from 0 to +40°C (+32 to 

1

04°F) and relative humidity from 0% to 85%

(noncondensing), at altitudes up to 

1

0,000 feet above sea level.

Interconnect

All external interface connectors are RJ

11

type and/or two piece screw terminal pluggable Euro-connector type.

Summary of Contents for DFT120

Page 1: ...Digital Feedback Terminator DFT120 Model Installation and Use Manual 2003 Bogen Communications Inc All rights reserved Specifications subject to change without notice 54 5036 02C 0310 Printed in U S A...

Page 2: ...find the following booklet How To Identify and Resolve Radio TV Interference Problems helpful This booklet was pre pared by the Federal Communications Commission FCC and is available from the U S Gov...

Page 3: ...witch 9 Audio Out Volume Control 10 Audio Out Impedance Selector 10 Audio Out 10 General Purpose I O Connector 10 Setting Setup Switches 10 Configuration Switch Position 10 Record Activation 10 DTMF S...

Page 4: ...Specifications Physical Maximum dimension 10 W x 11 2 H x 61 2 D Weight 4 5 lb 2 kg Electrical Frequency Response 6 8 kHz and 60 dB of dynamic range Page Audio Input 600 ohms transformer isolated wit...

Page 5: ...r 8 ohm or 600 ohm 8 Audio Out RJ11 jack for Audio Out w Status Signal Connector 9 Setup Switches Dip switch settings control unit feature operation 10 I O Connections Various control inputs and statu...

Page 6: ...T120 to the PBX and the paging system 3 Set DIP switches to the desired operation 4 Power unit up 5 Test unit operation Mounting the Unit To mount the unit 1 Select a space on the wall rack or table M...

Page 7: ...naling into a zone paging device For telephone systems that cannot provide a loop start or a contact closure the DFT120 can be triggered solely by audio detection In this configuration when audio is d...

Page 8: ...has been used it will issue a busy back tone whenever it is accessed until additional message space is made available by playing the stored pages Override Operation The DFT120 includes an override in...

Page 9: ...ct closure is required for supervision Page In Input 6 pin RJ11 style connector Pin 1 Not used Pin 2 Page In Control Connect to Control Pin 5 to operate Pin 3 Ring Pin 4 Tip Pin 5 Control Pin 6 Not us...

Page 10: ...led with Pin 2 of Override RJ11 jack 4 STOP control 5 PLAY control 6 PAGE IN control paralleled with Pin 2 of Page In RJ11 jack 7 BUSY 8 BUSY 9 PLAY 10 PLAY 11 RECORD 12 RECORD Setting Setup Switches...

Page 11: ...tem Most paging systems require a lim ited number of tones to be recorded because of zone controlling equipment but if a certain number of tones is exceeded the DFT120 will abort that particular recor...

Page 12: ...ext mes sage is played 10 Number of Plays UP One Play message one time factory setting DN Two Play message two times Play Delay To make the page sequence more intelligible a pause can be inserted betw...

Page 13: ...of the record process If the unit is recording at the same time it is playing a Stop command will only stop the currently playing message If the Stop control is maintained the DFT120 will stop the cu...

Page 14: ...recording playback tones etc Play Contact Normally Open contact closure becomes shorted whenever the DFT120 is playing audio through the output It will be shorted during the pause between the message...

Page 15: ...ing on the paging system used The DFT120 is typically installed between the telephone system and the paging system It interfaces with the paging controller in a zone pag ing environment and with the a...

Page 16: ...50 Spring Street Ramsey NJ 07446 U S A Tel 201 934 8500 Fax 201 934 9832 www bogen com...

Reviews: