background image

2

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN

NOTICE:

Every effort was made to ensure that the information in this guide was complete

and accurate at the time of printing. However, information is subject to change.

WARNING: 

To reduce the risk of Fire or Electric Shock, Do Not Expose this apparatus

to rain or moisture.

Apparatus shall not be exposed to dripping or splashing and no objects filled with liquids,
such as vases shall be placed on the apparatus.

WARNING: 

Only connect unit to AC mains outlet providing protective earthing connection.

NOTE:

Mains plug is used as disconnect device from the mains and shall remain readily

accessible and operable.

CAUTION: 

These servicing instructions are for use by qualified service personnel only. To reduce the

risk of electric shock, do not perform any servicing other than that contained in the operating

instructions unless you are qualified to do so.

CAUTION: DO NOT INSTALL OR PLACE THIS UNIT IN A BOOKCASE, BUILT-IN CABINET, OR IN
ANOTHER CONFINED SPACE. ENSURE THE UNIT IS WELL VENTILATED. TO PREVENT THE RISK 
OF SHOCK OR FIRE HAZARD DUE TO OVERHEATING, ENSURE THAT CURTAINS AND ANY OTHER
MATERIALS DO NOT OBSTRUCT THE VENTILATION VENTS.

Always follow these basic safety precautions when installing and using the unit:

IMPORTANT SAFETY INSTRUCTIONS

1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Do not use this apparatus near water.
6. Clean unit with dry cloth. 
7. Do not block any ventilation openings. Install in accordance with the manufacturer's instructions.
8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus

(including amplifiers) that produce heat.

9. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two

blades with one wider than the other. A grounding-type plug has two blades and a third grounding
prong. The wide blade, or the third prong, are provided for your safety. If the provided plug does not
fit into your outlet, consult an electrician for replacement of the obsolete outlet.

10. Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles,

and the point where they exit from the apparatus.

11. Only use attachments/accessories specified by the manufacturer.
12. Unplug this apparatus during lightning storms or when not used for long periods of time.

13. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been

damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or
objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not 
operate normally, or has been dropped.

CAUTION: TO PREVENT THE RISK OF ELECTRIC
SHOCK, DO NOT REMOVE ANY FRONT/BACK COVERS
OR PANELS. NO USER-SERVICEABLE PARTS INSIDE. 
REFER SERVICING TO QUALIFIED PERSONNEL.

The exclamation point within an equilateral triangle is
intended to alert the user to the presence of important
operating and maintenance (servicing) instructions.

The lightning flash with arrowhead symbol, within an equi-
lateral triangle, is intended to alert the user to the presence
of uninsulated "dangerous voltage" within the product's
enclosure that may be of sufficient magnitude to constitute
a risk of electric shock to persons.

Summary of Contents for CC4052m

Page 1: ...CC Series Amplifier Model CC4052m Installation and Use Manual 2012 Bogen Communications Inc All rights reserved Specifications subject to change without notice 54 2212 01A 1303 ...

Page 2: ...o not install near any heat sources such as radiators heat registers stoves or other apparatus including amplifiers that produce heat 9 Do not defeat the safety purpose of the polarized or grounding type plug A polarized plug has two blades with one wider than the other A grounding type plug has two blades and a third grounding prong The wide blade or the third prong are provided for your safety I...

Page 3: ...d TEL Input Balanced LINE MIC Inputs 1 3 Unbalanced LINE Inputs 1 3 AUX Input 4 24V DC IN Operation 8 9 Level Controls Bass and Treble Controls TEL Input Level Control LINE MIC Selector Switch Mute Send MOH Output Level Control MOH Source Select Media Player Cooling 10 Accessories Rack Mount Adapter 10 Technical Specifications 10 Limited Warranty Exclusion of Certain Damages 11 ...

Page 4: ...H source 2 Bass Treble Separate controls for bass and treble allow adjustment of tonal quality 3 Input Level Controls A front mounted level control is provided for each rear input 4 Peak Indicator This indicator illuminates when the amplifier reaches peak output level 5 Signal Indicator This indicator illuminates when a signal is present at any input 6 Power Switch Indicator The amplifier power is...

Page 5: ...balanced input with selectable gain suitable for line level signals including dry loop telephone signals as well as balanced low impedance micro phones The associated slide switch sets the input for LINE MIC or PP MIC with phantom power This input can be set to mute Inputs 2 3 4 and Media Player when active This input is always muted by the TEL Input 13 Inputs 2 3 Balanced LINE MIC Inputs 2 and 3 ...

Page 6: ...types of MOH outputs can be selected a 1 watt 8 ohm unbal anced output and a 600 ohm transformer isolated balanced output Most current telephone systems will be compatible with the 600 ohm output Some older switches require a higher power signal source to drive the telephone load For these systems use the 1W 8 ohm output REC Output This set of RCA connectors provide a signal level output of the pr...

Page 7: ... phase of the signal so even if the and connections were reversed the amp would still work fine See the Operation section for details on setting the associated switches Input 1 has the ability to mute Inputs 2 3 and Media Player when active depend ing on the setting of the Mute Send switch These inputs are always muted by TEL Input when active Unbalanced LINE Inputs 1 to 3 Inputs 1 through 3 can b...

Page 8: ... For balanced line level or telephone level signals the switch should be set to LINE If using the input with an unbalanced line level signal the switch should also be set to LINE see the section on input connections for instructions on unbalanced input wiring Mute Send The mute send switch is used to disable Input 1 from muting Inputs 2 3 4 and Media Player Set this switch to ON if voice activated...

Page 9: ...buttons on the front of the media player control operation functions and an LCD screen displays status information see below Media player program material is muted by both the TEL Input and Input 1 when Mute Send is on Media Player program is never muted on the MOH Output LCD Display OOO5 O2 15 REC MP3 SD USB RANDOM POP CLASSIC JAZZ ROCK ALL ALL RANDOM 2 3 4 5 6 7 8 9 1 11 10 Repeats current selec...

Page 10: ...mV approx VOX Release Delay 1 sec Muting Level 60 dBr Media Player Format MP3 and WMA files Type USB and SD MMC Max Capacity 16 GB Phantom Power 12V DC min 18V DC max Max Ambient Temp 100 deg F non condensing Thermal Emissions 141 5 BTU hr full power External Supply 24V DC 3A Max Unit Dimensions 8 1 4 W x 3 1 2 H x 10 3 8 D Product Weight 11 lb Listings Listed to UL Standard 60065 for US and Canad...

Page 11: ...AND EXCLUDED TO THE MAXIMUM EXTENT ALLOWABLE BY LAW Bogen s liability arising out of the manufacture sale or supplying of products or their use or disposition whether based upon warranty contract tort or otherwise shall be limited to the price of the product IN NO EVENT SHALL BOGEN BE LIABLE FOR SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES INCLUDING BUT NOT LIMITED TO LOSS OF PROFITS LOSS OF DATA O...

Page 12: ...50 Spring Street Ramsey NJ 07446 USA Tel 201 934 8500 Fax 201 934 9832 www bogen com ...

Reviews: