Notice

Every effort was made to ensure that the information in this manual was complete and accurate at
the time of printing. However, information is subject to change.

Important Safety Information

Always follow these basic safety precautions when installing and using the system:

1

.

Read and understand all instructions.

2.

Follow all warnings and instructions marked on the product.

3.

DO NOT block or cover the ventilation slots and openings.

4.

Never spill liquid on the product or drop objects into the ventilation slots and openings. Doing
so may result in serious damage to the components.

5.

Repair or service must be performed by a factory authorized repair facility.

6.

DO NOT install telephone wiring during a lightning storm.

7.

DO NOT install telephone jacks in a wet location unless the jack is specifically designed for
wet locations.

8.

Never touch uninsulated wires or terminals, unless the line has been disconnected at the 
paging or controller interface.

9.

Use caution when installing or modifying paging or control lines.

Service Requirements

In the event of equipment malfunction, all repairs should be performed by Bogen or an authorized
agent. It is the responsibility of users requiring service to report the need for service to Bogen or
to one of our authorized agents. Service can be facilitated through our office at:
Bogen Communications, Inc.
50 Spring Street, Ramsey, NJ 07446, USA
Tel.

201-934-8500

Bogen’s Applications Department may be reached at:

1

-800-999-2809.

Summary of Contents for ADP1

Page 1: ...Analog Door Phone Model ADP1 Installation and Use Manual 2004 Bogen Communications Inc All rights reserved Specifications subject to change without notice 54 2098 01B 0607 ...

Page 2: ...ctory authorized repair facility 6 DO NOT install telephone wiring during a lightning storm 7 DO NOT install telephone jacks in a wet location unless the jack is specifically designed for wet locations 8 Never touch uninsulated wires or terminals unless the line has been disconnected at the paging or controller interface 9 Use caution when installing or modifying paging or control lines Service Re...

Page 3: ...els as well as a selectable Auto Answer feature to allow for remote monitoring The ADP1 also includes an adjustable and defeatable call timer and can respond to forward disconnect signals The ADP1 features a heavy gauge stainless steel gasketed faceplate plastic cone speaker and faceplate to electrical box user supplied gasketing to protect against vandals and varying weather conditions A dress be...

Page 4: ...n only background noise not active audio is detected 5 Active LED For use when installing and troubleshooting the LED indicates that the unit is active off hook when lit 6 Timer Timer Duration POT The ADP1 can be configured to automatically disconnect a call after a preset amount of time has elapsed The timer can be set between 15 seconds and 2 minutes The timer is activated by pressing the button...

Page 5: ...operation using the RJ11 or directly to the screw terminals depending on how the lines are terminated The connections to the terminal block are not polarity sensitive Surge Protection To increase surge protection connect a protective Earth Ground to the spare lug provided A ring lug is provided to which the protective ground lead is crimped Reassemble the lug to post as shown ...

Page 6: ...aps between the box and the rough opening 3 Attach the self adhesive gasket to the back side of the bezel 4 Make electrical connections and attach the faceplate to the electrical box while capturing the bezel between the two using the four hex drive screws tool provided The faceplate fits into the depression in the bezel Surface Mounting the ADP1 Indoor Outdoor 1 Mount electrical box 2 Make electr...

Page 7: ...tion 15 seconds to 2 minutes Loop Current Loss Disconnect 300 ms minimum Ring Voltage 40V AC RMS minimum REN 0 7A Connections 2 position pluggable terminal block Earth Ground lug Dimensions 5 W x 5 H x 21 4 D fully assembled 45 8 W x 45 8 H x 2 D aluminum box Product Weight 4 lb ...

Page 8: ...ITNESS FOR A PARTICULAR PURPOSE ARE HERE BY DISCLAIMED AND EXCLUDEDTOTHE MAXIMUM EXTENT ALLOW ABLE BY LAW Bogen s liability arising out of the manufacture sale or supplying of products or their use or disposition whether based upon warranty contract tort or oth erwise shall be limited to the price of the product In no event shall Bogen be liable for special incidental or consequential damages incl...

Reviews: