RATIO.pm6.5 - USA
Page 1.9
RATIO
BOGE – RATIO compressor control for screw compressors
Operation
1.4
Operation
RATIO
Press
↓
-key a fifth time
→
and the display shows
the operating time (in hours) until the compressor
servicing and the Running time and Servicing sym-
bols (spanner).
Press
↓
-key a sixth time
→
and the display shows
the operating time until the next Motor servicing and
the symbols O (here for motor), running time and
servicing (spanner).
Compressor
servicing
Motor servicing
Press
↓
-key a seventh time
→
and the display
shows the 1000-output cycle servicing counter with
the exponent 10
3
(x 1000), the Load-cycle symbol,
the circle (here for receiver) and the servicing
symbol (spanner), meaning the number of possible
output cycles until the next receiver inspection or
change of wearing parts.
Next receiver
servicing/change
of wearing parts
depending on
output cycles
means: 500hrs until the next
compressor servicing
means: 1000hrs until the next
motor servicing
Press
↓
-key a third time
→
and the display shows
the Idling time counter in h (hours) and the Idling
symbol:
.
Idling time
means: 2hrs idling time
Press
↓
-key a fourth time
→
and the display shows
the 1000-output-cycles counter with the exponent
10
3
(x 1000), the load cycle symbol and the circle
(here: receiver).
Output-cycle-
counter
means: 12 x 10
3
= 12000 output
cycles
means: 20 x 10
3
= 20000 Load
cycles until the next receiver
servicing or change of wearing
parts
Operating/control element
Function
Operation/ Explanation