Maintenance
6.3
Maintenance work compressor
Page 60
BOGE Operating instructions for C 16 N...C 30 N, C 16 F N...C 30 F N series screw compressors
–
Switch off the compressor using the OFF button.
Fig. 6.10: Cleaning the compressed air/oil cooling unit
Function check of the
safety valve
Have the function of the safety valve checked exclusively by BOGE Service
personnel.
Interval: after approximately 3,000 operating hours but at least once a year.
WARNING: Risk of injury!
Actuate emergency-stop switch/button, open mains disconnecting device
and secure by means of lock out tag out.
WARNING!
Do not use any sharp objects for cleaning!
These could damage the cooling unit.
–
Blow down the dirt with
compressed air in the
opposite direction to the
normal cooling air flow.
Vacuum out the dirt using
an industrial vacuum
cleaner.
If the cooling unit is exces-
sively soiled (cleaning is no
longer possible with com-
pressed air), have it disas-
sembled and cleaned by
BOGE service.
WARNING: Risk of injury!
Risk of injury from flying parts caused by overpressure, e.g. pressu-
rised components bursting or detonating!
Risk of injury due to sudden discharge of hot compressed air!
It is forbidden to operate the compressor without the installed safety devices.
A safety valve prevents inadmissible overpressure.
The specified final compression pressure must not be exceeded.
Observe the statutory regulations applicable in the installation location for
operating safety devices against overpressure.