C. KEYS AND FUNCTIONS:
MODE KEY
:
Press Mode to choose functions. Keep pressing Mode Key for 2 seconds, LCD fully
displays for 1 second and the previous values of all function will be reset to 0.
ENTER KEY
:
Under “STOP” condition, press “ENTER” to preset the values of all functions.
Under “START” condition, press “ENTER” to select the
display of all functions.
SET KEY
:
Press “SET” key in setting mode to select the functions for setting values.
NOTES:
1. If the display panel does not work: replace the batteries and check to see if
the monitor is connected. * Use 2 pieces 1.5V of size AA batteries.
2. The monitor start automatically when exercising or pushing buttons.
3. The monitor will automatically shut off, if Inactive for over 6 minutes.
4. “
K
” or “
M
” indicates either kilometer or mile.
RESET KEY:
Press the button over 3 seconds will reset all functional values to zero except
ODO (odometer) value.
When all the functions display, the symbol of the pulse will not appear
SPECIFICATION:
FUNCTION
Auto Scan Every 6 seconds
Speed
Unit: KPH or MPH (According to inside setting)
Distance
0.1-999.9 Mile or KM (According to inside setting)
Time
0:00-99:59 (Minute: Second)
Odometer 0.1-999.9 KM or Mile (According to inside setting)
Calorie
0.1-999.9 Kcal
Pulse
40-240 BPM
Sensor
No-contact magnetic type
Battery type
Two pieces of SIZE-AAA
Operation temperature
0
℃
- +40
℃
( 32
℉
- 104
℉
)
6