![Bodine ELI-S-10 Installation Instructions Download Page 2](http://html.mh-extra.com/html/bodine/eli-s-10/eli-s-10_installation-instructions_2782484002.webp)
> The backup nano inverter will be located between the AC power sources and the AC ballast/driver as shown in
wiring diagram section of instructions.
> NOTE: The backup nano inverter may be installed in close proximity to the fixture or remote from the fixture.
The maximum remote distance using 16 AWG wire is 100 ft. Contact the factory for more information.
> The AC ballast/driver receives power from the backup nano inverter. Identify the output wires of the backup
nano inverter by the presence of the red/black and red/white leads.
NOTE: Make sure that the necessary branch circuit wiring is available. An unswitched
source of power is required. The unswitched and switched power source must be fed
from the same branch circuit.
WARNING: TO PREVENT HIGH VOLTAGE FROM BEING PRESENT ON THE RED/BLACK AND
RED/WHITE OUTPUT LEADS PRIOR TO INSTALLATION, BLUE CONNECTOR MUST BE OPEN.
JOIN BLUE UNIT ENABLE WIRES AFTER INSTALLATION IS COMPLETE AND AC POWER IS
SUPPLIED.
INSTALLING THE BACKUP NANO INVERTER
> Disconnect all power sources to the lighting fixture and ensure they are locked out during installation or
maintenance.
> The AC ballast/driver must be sourced from the backup nano inverter.
> Select a suitable location for the backup nano inverter and install such that its output leads can connect to
the input leads of the AC ballast/driver.
> See Illustration 1, for typical installation and select appropriate mounting method.
STEP #1
DISCONNECT AC POWER FROM FIXTURE
INSTALLATION
2
This product is suitable for field installation with suitable luminaires including LED, fluorescent, and incandescent luminaires
with 0-10V dimming capability. The 0-10V dimming capability may not be necessary for luminaires that operate under 10VA.
This product has been designed to reliably interface with a wide selection of luminaires which are electrically compatible
with 120 or 277 VAC at 60Hz and a 0-10V dimming interface. However, compatibility cannot be guaranteed with all current
and future luminaire systems.
Compatibility testing of the end-use system is recommended. Please contact the factory with any questions. After installa-
tion, it will be necessary to measure the egress lighting illumination levels to ensure it complies with national, state, and
local code requirements.
NOTE: Considerations must be made to protect the wires of the ELI-S-10 if installed outside of the luminaire.
If the application requires the ELI-S-10 to be mounted on
top of the luminare please use Model ELI-S-10C instead or
wire bundle cover kit (RMC-60). Please note, the RMC-60 kit
contains enough parts to install two products.
Nano
Inverter
ILLUSTRATION 1
> Verify that the blue connector is disconnected. Note that the unswitched hot connects to the red input lead
of the backup nano inverter.
STEP #2