10
www.bodine-electric.com
Figure 1 - Detail of Control Circuit Board in Enclosure.
A
B
C
Motor F
use
AC Neutral
Motor
Phase
Outputs
Motor Fuse
Horsepower Settings
Commutation
Sensor Inputs
Control Inputs
Line Fuse
AC Line
MAX speed adjust
(CW increase)
MIN speed adjust
(CW increase)
Acceleration time
(CW increase)
Deceleration time
(CW increase)
Torque adjust
(CW increase)
External Speed Pot Connections
RED FAULT
LIGHT
(Indicates a
problem with the
commutation
sensor
connections)
(4.55 Typ.)
(4.64)
3.88 Max.
1.48 Min.
(.57 Typ.)
(.57 Typ.)
(9.20) Typ.
8.45 Max.
Shown with optional
mounting brackets in the
vertical position.
Figure 3 - Horsepower (DIP Switch) Settings and Fuse Selection Chart
10
Control
Motor or
Rated
DIP Switch
Line
Motor
AC rms
Model
Gearmotor
Speed Levers in the
Fuse
Fuse
Input
Number
Type
Hp
(RPM) “On” Position
(F1)
(F2)
Current
22B2… 1/16
2, 6, 8
MDA 6/10
2.7
22B3… 1/11
1, 2, 6, 8
MDA 8/10
3.6
ABL-3912E
22B4… 1/8
2500
1, 3, 6, 8
ABC 15 MDA 1-1/4
4.8
34B3… 1/5
1, 2, 3, 6, 8
MDA 1-1/2
6.7
34B4… 1/4
2, 4, 6, 8
MDA 2
8.0
34B6… 3/8
1, 5, 6, 8
MDA 2-1/2
11.1
ABL-3913E
22B4… 1/5
10,000
1, 2, 3, 6, 8
ABC 15 MDA 1-1/2
6.7
34B4… 1/3
1, 3, 4, 6, 8
MDA 2-1/2
9.5
Figure 2 - Horsepower (DIP Switch) Settings and Motor Fuse Selection Chart
Figure 1 - Detail of Control Circuit Board in Enclosure.
Typical MAX Motor Speeds with 10 K Speed Pot
DIP Switch
7
DIP Switch 8 CCW MAX
Pot
Calibrated
MAX Pot
CW MAX
Pot
1
T-Out Pulse
Width (µS)
ON
ON
4400
6600
8800
275
ON
OFF
6600
10,000
13,000
190
Factory
Setting
OFF
ON
6600
10,000
13,000
190
OFF
OFF
13,000
20,000
26,000
90
Figure 2 – DIP Switch 7 and 8 Speed Range Settings
1. Max. Speed obtainable is dependent on motor winding (voltage, speed rating, resistance),
line voltage and load conditions.
Summary of Contents for 3912
Page 22: ...NOTES ...