background image

10

www.bodine-electric.com

The following three figures illustrate three different recommended 

connections between the motor and the voltage source or control (inverter). 

When a controller (inverter) is used, refer to the controller’s documentation 

for additional information regarding operation of the system.

AC Supply

(N.O.)

(N.C.)

AC Inverter

(L1)

(L2)
(U)

(V)

(W)

Power Supply

Connections
Motor Phase

Connections

Class I, Division 1 Environment

34R6BXPP Motor or Gearmotor

Motor Phases/Thermal Switch

Black

Thermal

Switch

White
White

Blue

Red

Green-Yellow Tracer

Frame

U

W

V

L1
L2

Figure 4b – Electric Connections – Thermal Switch with AC Relay to Interrupt Supply

Class I, Division 1 Environment

34R6BXPP Motor or Gearmotor

Motor Phases/Thermal Switch

Black

Thermal

Switch

White
White

Blue

Red

Green-Yellow Tracer

Frame

U

W

V

AC Inverter

AC Supply

(L1)

L1

L2

Enable Input

Common

(L2)
(U)

(V)

(W)

Power Supply

Connections
Motor Phase

Connections

Figure 4a – Electric Connections – Thermal Switch with Logic Control to Disable Motor Power

Summary of Contents for 34R6BXPP

Page 1: ... Phase Inverter Duty 230VAC or 460VAC This apparatus is suitable for use in Hazardous Locations Class I Division 1 Groups C D Instructions for Installation and Operation UL LISTED F O R O P E R A T I O N C L A S S I D I V 1 H A Z A R D O U S L O C A T I O NS PROOF IP 66 EX www bodine electric com ...

Page 2: ...dine Electric Company Important Safety Precautions 3 Product Specifications 4 Installation 5 Step 1 Mount the 34R6BXPP Motor or Gearmotor 6 Step 2 Attach a Conduit Outlet Box to the Motor 8 Step 3 Make Electrical Connections 8 Step 4 Operate the 34R6BXPP Motor or Gearmotor 12 Troubleshooting 13 Bodine Limited Warranty 14 FIGURES Figure 1a Dimensions for Standard 34R6BXPP Motor 6 Figure 1b Dimensio...

Page 3: ...rve those paragraphs with the safety alert symbol This indicates a potentially hazardous situation which if not avoided could result in death or serious injury WARNING AVERTISSEMENT CAUTION To reduce the risk of ignition of hazardous atmospheres disconnect the equipment from the supply circuit before opening Keep assembly tightly closed when in operation Leads factory sealed Do not disassemble any...

Page 4: ...gear ratio that is offered TABLE 1 Parameter Specification Locations Hazardous locations Class I Division 1 Groups C D or unclassified non hazardous locations Temperature Code T4A or T3C Horsepower HP Volts 230 VAC 3 Phase or 460 VAC 3 Phase separate models Line Frequency 60 Hz Inverter Frequency 10 120 Hz for motors 10 90 Hz for gearmotors Ambient Temperature 20C to 40C Insulation F8 TABLE 2 LINE...

Page 5: ... equipment from the supply circuit before opening Keep assembly tightly closed when in operation Leads factory sealed Do not disassemble any part of this product as that will compromise its safety in hazardous atmospheres This product should be installed inspected and maintained by a qualified electrician only in accordance with all applicable electrical codes ATTENTION Pour réduire le risque d in...

Page 6: ...ndard 34R6BXPP Motor 9 534 Max 4 78 Max sq 483 010 2 06 03 ø 6250 1875 1855 x 1 38 long key 1 NPT x 11 threads per i 6245 125 125 2 13 sq Flange 7 16 17 Num leads m 50 4 885 Max 2x 800 2x 39Base mounting holes 4x1 4 20UNC 2B 47 min deep Ba 10 2 06 03 4x 3 8 16 UNC 2B 90 1 apart on ø5 875 010 b c 4x 1 4 20 UNC 2B 31 Min Deep 90 0 apart on ø3 750 b c ø 4 500 4 497 5 32 02 sq ø 3 000 2 997 ø 6250 187...

Page 7: ... unting 55 sq ng key Base mounting holes 3 380 Typ ø 6250 6245 3 390 006 1875 1855 sq x 1 12 Long Key 3 380 Typ 50 06 Typ 1 NPT x 11 1 2 Threads per inch 4 01 Max 1 590 Typ 90 1 50 ø1 536 016 Not Machined If mounting from the four 20 UNC 2B base holes the screw length should not exceed a maximum thread engagement depth of 0 45 See Figure 1a and 1b for the location of the mounting holes on Bodine s...

Page 8: ... Installation 1 in NPT 11 5 threads per inch female thread O ring Cover A A Figure 2 A Typical Conduit Outlet Box Step 3 Make Electrical Connections WARNING AVERTISSEMENT CAUTION To reduce the risk of ignition of hazardous atmospheres disconnect the equipment from the supply circuit before opening Keep assembly tightly closed when in operation Leads factory sealed Do not disassemble any part of th...

Page 9: ...ne fois que la température a suffisamment refroidi pour permettre aux contacts de protection de se réinitialiser et si une alimentation CA est présente Installation of this motor requires either a 3 phase AC voltage source or a controller inverter capable of operating a 3 Phase AC induction motor The controller must incorporate or be used in conjunction with one of the following capabilities to pr...

Page 10: ...s I Division 1 Environment 34R6BXPP Motor or Gearmotor Motor Phases Thermal Switch Black Thermal Switch White White Blue Red Green Yellow Tracer Frame U W V L1 L2 Figure 4b Electric Connections Thermal Switch with AC Relay to Interrupt Supply Class I Division 1 Environment 34R6BXPP Motor or Gearmotor Motor Phases Thermal Switch Black Thermal Switch White White Blue Red Green Yellow Tracer Frame U ...

Page 11: ... N O Figure 4c Electric Connections Thermal Switch with 3 Pole AC Relay to Interrupt Supply THERMAL SWITCH NOTES Motor thermal switch must be connected to interrupt power to the controller and or motor windings when the contact opens to limit motor temperature Thermal switch contact ratings AC 250VAC 2 5A 1 0 P F 250VAC 1 6A 0 6 P F DC 24VDC 3 5A 48VDC 1 5A WARNING motor will automatically restart...

Page 12: ...ne Ne démontez aucune pièce de ce produit car cela compromettrait sa sécurité dans les atmosphères dangereuses Ce produit doit étre installè inspecté et entretenu par un électricien qualifié seulement conformément avec tous les codes de l électricité pertinents CAUTION Check that gearmotor is securely mounted Check all rotating members Be sure keys pulleys etc are securely fastened and safety guar...

Page 13: ...usine Ne démontez aucune pièce de ce produit car cela compromettrait sa sécurité dans les atmosphères dangereuses Ce produit doit étre installè inspecté et entretenu par un électricien qualifié seulement conformément avec tous les codes de l électricité pertinents If you encounter a problem read all instructions and double check the wiring Even if the 34R6BXPP motor or gearmotor itself shows obvio...

Page 14: ...odine Electric or to the nearest Bodine Authorized Service Center At its option all return shipments are F O B Bodine s plant or Authorized Service Center Bodine is not responsible for removal installation or any other incidental expenses incurred in shipping the products to or from Bodine This warranty is in lieu of any other expressed or implied warranty including but not limited to any implied ...

Page 15: ...www bodine electric com 15 NOTES ...

Page 16: ...stry For complete specifications 3D CAD drawings or to order online visit bodine electric com info bodine electric com www bodine electric com 201 Northfield Rd Northfield IL 60093 USA Tel 773 478 3515 Visit www bodine electric com for more information 07401151 B Bodine offers over 1 400 standard gearmotors motors and system matched speed controls ...

Reviews: