![Bodet Opalys 14 Installation And Operating Instructions Manual Download Page 25](http://html.mh-extra.com/html/bodet/opalys-14/opalys-14_installation-and-operating-instructions-manual_2782348025.webp)
25
4.3 AFNOR or impulses slave Clock
The time on the AFNOR/Irig-b slave clock will be set automatically.
After a reset or a time setting, the clock search each minute, during 20 seconds, until it get
synchronised.
Minute or ½ minute slave clocks must be set to the time of time distribution network.
Remark : See the chapter “Technician Menu” page 33 to parameter to time distribution.
Caution :
In case of no AFNOR synchronisation message :
- After powering up the clock, no time will be displayed and the clock will show two dots.
It is always possible to modify the time setting but the time will not be running and the cock will
only display the two points.
4.4 DHF clock
Caution: when installing the clock, the master clock Sigma or the transmitter must be set to INIT
mode.
DHF clocks are self-setting clocks.
- After powering up the clock, the displays will show INIT for 5 seconds then 00:00.
The synchronisation search is limited to 4 hours. Beyond, the clock stops searching and
displays only 2 fixed dots. A press on one of the keys will restart the synchronisation search
for 4 hours.
It memorises the address of the transmitter and switches to normal mode automatically when
time is received.