Radio time synchronisation secondary transmitter

DHF V2 927241

Start up instructions

Mount the repeater in the area covered

by the transmitter. Under no

circumstances the transmitter should be

directly mounted on a metallic surface. 

 The DHF repeater V2 (ref.: 927241) enables to extend an area non

covered by the main DHF transmitter.

1

2

Repeater

Transmitter

4

 Connect the 230V (A) and secure the

powercable with the tie-wrap (B). Apply

the power. 

5

The DHF repeater must be 

paired with the DHF transmitter in order to 

work properly:

- Check that the « Init » mode yellow LED blinks. If 

not, set up again the repeater in « Initialization”

mode (part 6).

- Set up the main transmitter in “Init” mode.

- Once the signal of the main transmitter is

transmitted, the « Init » mode yellow LED is OFF

and the DHF transmission red LED is ON.

3

Status of the DHF repeater at the first start 

up.

- Power DIP (D) in position MED (125W).

- Power setting LED (C) ON (125 mW) 

on

,

- INIT mode yellow LED (E) blinks  (waiting for

the initialization of the main transmitter),

- DHF transmission Red LED (G) OFF.

A

B

G

7a

In “initialisation” mode, the LED (E) is

on. To switch the repeater back in Init

mode, short the two pins (F) for 3

seconds.

6

You can adapt the transmission power

with two DIP switches (D). LEDs (C) allow

you to check your setting.

If some clocks are not synchronised, increase the

transmission power.

The DHF repeater has a buzzer (H). It can be

activated from the master clock Sigma to help in

localizing the DHF repeater.

Té moin

émis sion 

7b

F

E

H

D

C

Leds

 

Dips

 

OFF (0W)

 

 

25mW

 

   125mW

 

 

500mW

 

0 0

1 0

0 1

1 1