VI - Dip switches setting
1st dip bank
On the 1st dip bank, dips 1 to 4 are used for the factory configuration of the panel.
Out of the factory the dips are set as follow:
Dip 1
Dip 2
Dip 3
Dip4
on ↑
on ↑
on ↑
off ↓
Dips 5 to 7 are used to identify each panel (If several panels are used on the same site
each panel must have its own number).
Dip 8 is to ON
↑
by default.
2nd dip bank (wireless HF only)
Dips 1 to 3 are used to set the installation number.
Dips 4 to 8 are unused. (to OFF
↓
by default).
2nd dip bank (wired mode)
Dips 1 to 8 are used OFF
↓
.
1st dip bank
2nd dip bank
Panel number
Dip 5
Dip 6
Dip 7
1
off ↓
on ↑
on ↑
2
on ↑
off ↓
on ↑
3
off ↓
off ↓
on ↑
4
on ↑
on ↑
off ↓
5
off ↓
on ↑
off ↓
6
on ↑
off ↓
off ↓
N° installation
Dip 1
Dip 2
Dip 3
1
off ↓
on ↑
on ↑
2
on ↑
off ↓
on ↑
3
off ↓
off ↓
on ↑
4
on ↑
on ↑
off ↓
5
off ↓
on ↑
off ↓
6
on ↑
off ↓
off ↓