Bodart&Gonay ARGOS 47GV74E Instructions For Use And Maintenance Manual Download Page 27

Argos  

 29 

Remove the stone supports and burner.

Remove the right fl ap (gas connection).

Connect the connection tube to the gas pipe (on the right of the appliance) (1/2” gas). The    

 

gas pipes must be free of dirt. Check there are no leaks, turn off  all gas appliances and check   

 

that the meter does not move for 5 minutes.

Connect the transformer. The transformer and the operating light (LED) should ideally be instal 

 

led in an accessible place outside the appliance.

Test the lighting of the pilot light (purge the fl ue). 

On fi rst lighting (start of season or new    

 

installation), air in the gas fl ue may disrupt fl ame detection. In this case, simply restart the  

 

appliance several times (to purge the fl ue), and you must open the door after each 

 unsuccessful 

att empt to light, in order to prevent gas accumulating in the combustion 

 chamber.

Position the fl ap, burner and stone support. Spread the gravel uniformly over the burners and  

 

stone support (an excess quantity may be provided depending on the model of fi replace). 

The  

 

pilot light outlet aperture MUST NOT BE BLOCKED BY THE GRAVEL.

Close the door using the tool.

Test the lighting a few times, and check that the fl ame is spread evenly. Reposition the gravel if  

 necessary.
 

Lighting the appliance: check there is a fl ame at the pilot light and wait at least for the litt le   

 

fl ame drawing to stop fl ashing before lighting the burner.

CHECK THAT THE APPLIANCE WORKS PROPERLY.Close the chimney and fi nish fi tt ing. 

Fan installation

The fan is fi tt ed from inside. 
aRCHIYou must:
 

1. 

Remove the stones if they are already in place.

 

2. 

Remove the stone support and burners.

 

3. 

Unscrew the large hatch (the one with the injectors and pilot light).

 

4. 

Place the fan inside the fi replace using silent blocks to position it. 

Att ention: the power lead may be plugged in either inside the fi replace or below it by passing it through the hole 
provided for this purpose; make sure the fan is installed the right way round! Blower directed towards the back. 

 

5. 

Replace the hatch, burners, stone support and stones.

 

6. 

Close the door.

 

Electricity supply -> Thermal switch -> Fan

Note:

The fan may be mounted under the fi replace. Put the fan through the lower hole. Position it using silent  

 

blocks in the four housings provided for this purpose. Leave room for the electrical lead.

A thermal switch activates the fan when the appliance is hot and cuts it out when the appliance cools  

 down.

Summary of Contents for ARGOS 47GV74E

Page 1: ...02 06 Argos 07DHARGA Instructions for use and maintenance Attention Remove the instructions from the replace and give them to the client along with the necessary instructions explanations and demonst...

Page 2: ...UARANTEE 1 GUARANTEE DURATION AND LIMITATION no guarantee on glass seals gravel and logs 2 years guarantee on valve command box thermocouple and pilot light gas accessories remote control fan 2 years...

Page 3: ...ns chimney installation misuse inadequate maintenance use of electrical or electronic components not approved by Bodart and Gonay any internal modi cation or alteration to the replace transportation a...

Page 4: ...0 mbar gaz nat No 47GV74E Double cat II 2E 3P II 2H3P Natural gas Cat I 2H I 2L I 2ELL I 2E Gaz LPG Cat I 3P Type ARGOS Gaz Category of gas Type CE E ciency Category NOx emission classi cation Nominal...

Page 5: ...Argos 5 3 DIMENSIONS...

Page 6: ...6 Argos...

Page 7: ...Argos 7...

Page 8: ...8 Argos...

Page 9: ...box and reception sensor fan control 4 Decorative plate 5 Concentric fume exhaust ue 6 Warm air duct and connection nozzle 7 Gravel 8 Pilot light thermocouple electrode 9 Stone support 10 Door opening...

Page 10: ...10 Argos 3 4 ON AUTO C 5 EXPLODED VIEW...

Page 11: ...Gas Natural VERTICAL PILOT LIGHT NATURAL GAS 26 27GV74031 TUBO ALIMENTACION GAS VALVULA A GAS SUPPLY PIPE VALVE ARGOS 740 AIR VENT 27 27GV14024 soporte valvula COSMOS SUPPORT VALVE COSMOS B F 28 27GV7...

Page 12: ...ates the replace s emergency shutdown mechanism The appliance is designed to cut out after 24 hours in operation Simply restart the appliance to put it back into operation FIRST FIRE On rst lighting s...

Page 13: ...Argos 13 3 4 3 4 3 4 3 4 3 4 3 4 3 4 3 4 3 4 3 4 3 4 3 4 C OFF C ON C ON C ON C ON C ON MANUAL MANUAL MANUAL MANUAL C 5 sec 1X 1X 10 sec 2 1 2 1 3 4 3 4 C ON MANUAL 3 4 C OFF 1X 2 1...

Page 14: ...unit and from the burner using a vacuum cleaner or brush Check that the connections are airtight and that the di erent parts of the appliance operate smoothly The Fan Unplug the electricity supply di...

Page 15: ...ss twice on the left SET button and then choose the temperature requi red using the plus and minus buttons Temperature information for adjusting the appliance is gathered every 6 minutes CHANGING TO M...

Page 16: ...nd replace the variator Clean or replace the lters down draught grills Clean the impeller blades Check chimney connection Check airtightness Check that the ue is free of blockages The fan is not worki...

Page 17: ...SET SET SET SET SET SET SET SET C OFF C OFF C ON C ON C ON C ON C ON MANUAL MANUAL MANUAL MANUAL 15 sec 1X 1X 10 sec 1 2 1 2 AUTO ON OFF cosmos ME 1 OK SET SET 1 THERMOSTATIQUE THERMOSTATIC THERMOSTA...

Page 18: ...SET SET SET SET SET C ON C ON AUTO AUTO C ON AUTO C C ON C OFF C C ON AUTO C ON AUTO C ON AUTO C C ON MANUAL MANUAL AUTO AUTO C C C 3 sec 5 sec 2X 1X 2X 1X 5 1X 1X ON 1X 1X ON ON MAX 4 sec amb T AUTO...

Page 19: ...Argos 19 5 sec ON OFF 1X ON OFF ON OFF 1X 10 sec ON OFF ON OFF 1 ON OFF cosmos 1 07DHCOSCM ARGOS...

Page 20: ...20 Argos Bodart Gonay s a Parc Artisanal de Harz Rue de Lambinon 3 B 4920 HARZE Aywaille 32 0 4 239 93 93 info b g be www b g be...

Page 21: ...gos 23 Argos 02 06 INSTALLATION INSTRUCTIONS 07DHARGA Attention Remove the instructions from the replace and give them to the client along with the necessary instructions explanations and demonstratio...

Page 22: ...system or the POUJOULAT 130 200 EI ue Only installations mentioned in the paragraph chimney installation are permitted Logs optional must be laid at on the coal bed gravel Your appliance has been corr...

Page 23: ...t out after 24 hours in operation Simply restart the appliance to put it back into operation FIRST FIRE On rst lighting start of season or new installation air in the gas ue may disrupt ame detection...

Page 24: ...onal horizontal metre add 1 metre of vertical duct For each additional 90 elbow add 1 metre of vertical duct For each additional 45 elbow add 0 5 metre of vertical duct Only install the draught limite...

Page 25: ...Argos 27 1 2 3 n 7 4 5 n 7 n 7 Installing the draught limiter...

Page 26: ...ide of the replace ONTOP or POUJOLAT ue Attention the temperatures of the outer surfaces of the chimney ue can reach 200 C Consequently do not use any combustible material near the chimney ue without...

Page 27: ...he tool Test the lighting a few times and check that the ame is spread evenly Reposition the gravel if necessary Lighting the appliance check there is a ame at the pilot light and wait at least for th...

Page 28: ...Argos Optifire Argos Infire 4 CHANGING THE INJECTOR FROM NATURAL GAS TO LPG Follow the rst 5 steps for dismantling the hatch Remove the main injector and the pilot light protection cage Replace the ma...

Page 29: ...H 17mm M 190 HELIOS GN Aardgas H 5mm M 130 COSMOS 100 LPG H 5mm M 175 COSMOS 145 LPG H 5mm M 115 HELIOS LPG H 10mm M 135 SOLARIS LPG H 5mm 4 Uniquement pour LPG Alleen voor LPG Only for LPG 1X 270 M 1...

Page 30: ...32 Argos SET SET SET C OFF C ON C ON SET C ON AUTO ON O N O N O F F 1X 1X OFF ON OFF 5 sec cosmos IT 1 1 2 1 2 ARGOS IT1 6 INITIALISATION...

Page 31: ...2 C F OFF 1X SET C ON AUTO cosmos IT 2 ARGOS IT2 Important warning The initialisation operation must only be done by a quali ed person and must only be done in rare cases It also requires work on the...

Page 32: ...2 2 DATA SHEET 4 3 DIMENSIONS 5 4 DESCRIPTION 9 5 EXPLODED VIEW 10 6 IMPORTANT RECOMMENDATIONS 12 7 MAINTENANCE 14 8 USING THE APPLIANCE 14 9 USING THE REMOTE CONTROL 15 Operating faults INSTALLATION...