CLKEXT
Syntax:
CLKEXT F
CLKEXT? F
Form:
Set & Query
Description:
Set external PLL frequency
Parameter:
F: external PLL frequency: CLK10, CLK80
RST value
-
Specified limit
-
Example:
CLKEXT CLK10
CLKEXT? => :CLKEXT: CLK10
RUN
Syntax:
RUN
Form:
Set
Description:
Software trigger
Parameter:
-
RST value
-
Example:
RUN
STORE
Syntax:
STORE n
Form:
Set
Description:
To store MODEL 745-T current configuration
Parameter:
n: configuration number
RST value
Specified limit
-
0 to 3
Example:
STORE 1
RECALL
Syntax:
RECALL n
Form:
Set
Description:
To recall a MODEL 745-T configuration previously stored
Parameter:
n: configuration number
RST value
Specified limit
-
0 to 3
Example:
RECALL 1
3/2/18
Berkeley Nucleonics Corporation, 2955 Kerner Blvd. San Rafael, CA 94901
[email protected], Call 800-234-7858 or Live-Chat @ www.berkeleynucleonics.com
27 of 35