background image

 

 

 

4.2 

230V SINGLE PHASE 

– With CS-7 Controller (CS-7 Controller provides on / off / high heat / low heat / fan only settings). 

 

Please make sure you have read the Safety instructions and that you are a suitably qualified electrician before continuing.  
Drawings show connections inside the black terminal box on the outside of the heater and the inside of the CS-7 Controller. 

Do NOT use power tools to undo or do up terminal screws.

 

Please Note:- Specified cable sizes are for typical installations, correction factors may need to be used when determining actual cable sizes. 

 
Standard Connection using CS-7 Controller 

Use 2.5mm² 3 Core Mains Cable (see note above). 
Use 2.5mm² 6 Core Cable to connect the heater to the CS-7 Controller (see note above). 
Remove  any  links 

that may be present in heater control box between terminals 1,2,3,4 or 5. 

 

Mains Cable 
Connect Brown wire 

– Terminal L. 

Connect Blue wire 

– Terminal N. 

Connect Green / Yellow wire 

– Terminal E or 

 

Heater to CS-7 Controller Cable 

– (Colours for reference only) 

Move the Dark Brown link cable from the centre switch terminal 1 to the centre switch terminal 3 (shown above by dark brown wire). 

Connect Brown wire 

– Terminal 1 or L of heater and Top Terminal L2 on right DP Switch of CS-7. 

Connect Grey wire 

– Terminal 2 of heater and Terminal L1 on right DP Switch of CS-7. 

Connect Red wire 

– Terminal 3 of heater and Centre Switch Terminal 1 of CS-7. 

Connect Black wire 

– Terminal 4 of heater and Terminal 1 on Left SP Switch of CS-7. 

Connect Yellow wire 

– Terminal 5 of heater and Top Terminal 2 on Left SP Switch of CS-7. 

Connect Green / Yellow wire 

– Terminal E or 

of heater and earth connection on CS-7. 

 

PLEASE CHECK ALL CONNECTIONS BEFORE TURNING ON AS INCORRECT WIRING IS NOT COVERED BY THE GUARANTEE. 

 

5. CHANGE MODE OF OPERATION 

 

 

The heater has two modes of operation to suit different applications. 

These two modes are selected by a switch on top of the heater next to the thermostat control knob. 

 

Mode I

 

With  the  switch  on  the  top  of  the  heater  in  the  “I”  position  both  the 
heater elements and the fan turn on and off with the thermostat. This 
mode is best used when using the heater as a space heater but may 
give long periods of on / off switching when the heater is used close to 
an external door in constant use or in confined spaces. 

 

Mode II

 

With the switch on the top of the h

eater in the “II” position the fan runs 

continuously  and  only  the  heating  elements  go  on  and  off  with  the 
thermostat. 

If you use this heater close to an external door in constant use or in a 
confined space, we recommend you use this mode of operation as it 
will tend to improve the response time of the thermostat. 

 

 