16. INSTALLATION. 

 
Wiring diagram 
 

 

Cool 

 

Common 

 

 
 
 

 

 
Fitting the Programmable Room 
Thermostat 

The ideal position to locate the 
Programmable Room Thermostat is 
about 1.5m above floor level, in a 
location where the thermostat is 
accessible, reasonably lit and free 
from extremes of temperature and 
draughts. Do not position the 
thermostat near sources of heat, 
such as radiators, lights, TV, direct 
sunlight or on an outside wall. 

 
 
Installation 

1. Remove  the  front  cover 

using a flat screwdriver in the two holes at the top of the programmer and separate from back plate. 

2. Fix the back plate directly on the wall using suitable wall plugs and screws. 

3. Unscrew the cover that is protecting the live terminals. Lift the cover to expose the wiring block, taking care to 

retain the screw. 

4. Complete the connections in accordance with the wiring diagram (page 6, Section 15). 
5. Replace  the  thermostat  onto  the  back  plate,  securing  the  bottom  of  the  thermostat  first  and  clicking  the 

thermostat into place. 

6. Insert the 2 x AA batteries provided in the battery compartment on the front of the thermostat, underneath the 

fascia.  The  Programmable  Room  Thermostat  is  now  installed  and  will  automatically  start  to  control  the  room 
temperature according to the factory pre-set programme as shown in the User Instructions. The display shows 
the correct time and date which is automatically set together with the actual room temperature. 

 

 

17. SETTING DELAYED START, OPTIMUM START, OPTIMUM STOP OR TPI. 

Note: TPI should only be used if connecting thermostat to a gas boiler and not used foe electric heating systems.

 

 
These settings may be accessed by 

1. Switch the slider to OFF position 
2. Press and keep holding the 

A

 and 

H

 buttons together (under the fascia) 

3. Now press the 

Next

      button to enter the Master settings. 

4. Release all 3 buttons. 
5. You should now see 

OP dl StAr

 in the bottom of the screen. If not repeat steps 1-4 

 

Now press the 

+

/

 buttons to choose between:- 

 

OFF

: The programme will run according to settings 

DS

 (dL StAr DS): When ON, the programmer will run in Delayed Start mode. The start of the next programme may be 

delayed up to 45 minutes depending on the room temperature 

S

 (OP StAr OS): When ON, the programmer will run in Optimum Start mode 

 
Now press the 

Next      

button and press the +/

– buttons to turn 

OP STOP

 (Optimum Stop) ON/OFF. 

Heat 

Summary of Contents for PROSTAT2

Page 1: ...otal Switch Rating 6 2 A 230VAC Contact Type SPDT Volt Free changeover contacts Plastic Thermoplastic flame retardant Number of Programs 4 or 6 Default 4 Number of Events per Day 4 6 Factory Pre Set P...

Page 2: ...ot notice the effect on the temperature but you should see a slight difference in your energy bill The following options are available BUT are only of use if using the thermostat with a gas boiler 4 C...

Page 3: ...C 4 Events Time Temp C 6 Events Time Temp C 6 Events Time Temp C 1 06 00 20 1 07 30 20 1 06 00 20 1 07 30 20 2 08 00 15 2 09 30 20 2 08 00 15 2 09 30 20 3 17 00 21 3 16 30 21 3 12 00 15 3 11 30 20 4 2...

Page 4: ...2 Press the button to increase the set temperature in increments of 0 5 c and or press the button to decrease the set temperature in increments of 0 5 c 3 Once the desired temperature is reached and...

Page 5: ...B If the display ever goes blank during normal operation the batteries need to be replaced with high quality alkaline cells The date time and factory pre set heating times will be retained assuming t...

Page 6: ...the front of the thermostat underneath the fascia The Programmable Room Thermostat is now installed and will automatically start to control the room temperature according to the factory pre set progra...

Page 7: ...gether under the fascia now press the Next button and the technical settings menu will be displayed Release all buttons 2 Press the Next button until you get to SER service interval Settings A numeric...

Page 8: ...and allow temporary manual override temperature Up Down arrows Full Lockout 5 This mode locks all keys slider The End user cannot adjust anything Setting the Maximum Program Temperature Press the Nex...

Reviews: