background image

4. SETTING THE OPERATION MODE (5/2 DAY, 7 DAY OR 24 HOUR). 

 

1. Switch the slider to 

PROG

.

 

2. Press

 +/

– 

buttons to move between 7 day, 5/2 day or 24hr operation.

 

5/2 Day operation 

is shown by MO, TU, WE, TH, FR flashing (5 Day) and then SA, SU flashing (2 Day).

 

7 Day operation 

is shown by just one day flashing at a time.

 

24 hr operation 

is shown by MO, TU, WE, TH, FR, SA, SU flashing at the same time. 

3. 

Wait  15  seconds  to  automatically  confirm  and  return  to  Run  mode  or  press 

Next

       

to  move  to  ‘Setting  the 

Programme’. 

 

5. SETTING THE PROGRAMME. 

 

1. Choose between 5/2 day, 7 day or 24 hr operation (see above steps 1-2). 
2. Press the 

Next

      button. The time will flash and P1 will be displayed (the 1st temperature event).

 

3. Press 

+/

 to set the time (10 minutes increments). Press the 

Next       

button and the temperature will flash.

 

4. Press 

+/

 to set the temperature (increments of 0.5°c). Press the 

Next

     button to go to the next time temperature 

event (e.g. P2).

 

5. Repeat steps 3 - 4 for all temperature events.

 

6. Press 

A

 to accept / confirm temperature events and move to the next day / block of days.

 

7. Repeat steps 3 - 6 until all days have been set. Then wait 15 seconds to automatically confirm and return to run 

mode or press the 

Home       

button.

 

 

6. ALL DAY SETTING. 

 

1. Switch the slider to 

AUTO

2. Press the 

A

 button under the fascia. The display will now show 

AL

 (All Day). 

3. Press the 

+

/

 button to set the temperature (increments of 0.5°c). 

4. The mode will quit by 00.00 that day. Press the 

Home

      button to cancel and return to Auto Mode. 

 

7. PERMANENT MANUAL OVERRIDES. 

 

1. Switch the slider to 

MAN

. MAN will appear in the display.

 

2. Press 

+/

– 

to adjust the temperature to the desired setting. This will set a constant temperature 24hrs a day.

 

3. Switch the slider to 

AUTO 

to revert back to Auto mode.

 

 

8. TEMPORARY MANUAL OVERRIDES.

 

 

1. To temporarily override the Programmable Room Thermostat status or temperature press the 

+/

 buttons. The Programme 

Events Display (e.g. P1) will no longer be shown. 

2. Press the 

+

 button to increase the set temperature in increments of 0.5°c and / or press the 

 button to decrease the set 

temperature in increments of 0.5°c. 

3. Once the desired temperature is reached (and after approx. 6 seconds) the time display will be replaced by a display indicating 

the time left to the next programme (the length of time the temporary override will run, if left unhindered) and the display then 
alternates between the time left and the current time. When the next ON / comfort programme is arrived at, the temporary 
override will end and Auto mode is reactivated. 

4. Press the 

Home

        button to cancel this function and reactivate Run mode. 

 

9. HOLIDAY MODE.

 

 

Holiday  Mode  saves  energy  by  letting  you  reduce  the  temperature  for  1  to  99  days  while  you  are  away  from  home, 
resuming normal operation on your return.

 

To set the Holiday Mode:

 

1. Make sure the Programmable Room Thermostat is in Auto mode. Press the 

button, underneath the fascia and 

the suitcase symbol will appear on the display and the number of days will flash.

 

2. Press 

+/

– 

to set the number of days you will be away.

 

3. Press the 

Next       

button and the temperature will flash. Press 

+/

– 

to set the desired temperature.

 

4. Press the 

Next       

or 

Home      

button or wait 15 seconds to automatically confirm.

 

5. The number of days chosen will alternate with time symbol on display and the number of days will count down.

 

6. Once  the  countdown  has  finished  the  thermostat  will  return  to  normal  operation.  It  may  be  advisable  to  set  the 

Holiday Mode 1 day less so the house is back up to temperature for your return.

 

7. To cancel the Holiday Mode setting or to exit the function at any time, press the 

Home       

button to revert back to 

Run mode.

 

 

10. FROST PROTECTION.

 

 

This function is provided as an option if it is desirable to turn the heating off permanently. It is usually used in summer.

 

To set the Frost Protection Mode:

 

1. 

Switch the slider to 

OFF

 to enter the Frost Protection Mode. The display will show the frost protection snowflake 

symbol and the set temperature will be 5°C.

 

2. 

Switch the slider to 

AUTO 

to exit Frost Protection Mode and revert to 

AUTO 

mode.

 

 

 

 

Summary of Contents for PROSTAT2

Page 1: ...otal Switch Rating 6 2 A 230VAC Contact Type SPDT Volt Free changeover contacts Plastic Thermoplastic flame retardant Number of Programs 4 or 6 Default 4 Number of Events per Day 4 6 Factory Pre Set P...

Page 2: ...ot notice the effect on the temperature but you should see a slight difference in your energy bill The following options are available BUT are only of use if using the thermostat with a gas boiler 4 C...

Page 3: ...C 4 Events Time Temp C 6 Events Time Temp C 6 Events Time Temp C 1 06 00 20 1 07 30 20 1 06 00 20 1 07 30 20 2 08 00 15 2 09 30 20 2 08 00 15 2 09 30 20 3 17 00 21 3 16 30 21 3 12 00 15 3 11 30 20 4 2...

Page 4: ...2 Press the button to increase the set temperature in increments of 0 5 c and or press the button to decrease the set temperature in increments of 0 5 c 3 Once the desired temperature is reached and...

Page 5: ...B If the display ever goes blank during normal operation the batteries need to be replaced with high quality alkaline cells The date time and factory pre set heating times will be retained assuming t...

Page 6: ...the front of the thermostat underneath the fascia The Programmable Room Thermostat is now installed and will automatically start to control the room temperature according to the factory pre set progra...

Page 7: ...gether under the fascia now press the Next button and the technical settings menu will be displayed Release all buttons 2 Press the Next button until you get to SER service interval Settings A numeric...

Page 8: ...and allow temporary manual override temperature Up Down arrows Full Lockout 5 This mode locks all keys slider The End user cannot adjust anything Setting the Maximum Program Temperature Press the Nex...

Reviews: