5 .   A D D I N G   A D D I T I O N A L   C O N T R O L S.  

 

You may add the following controls to the OUH2 Space Heater all of these controls if connected as shown in the wiring diagrams 
are protected by the heaters internal 3A fuse. 

 

 

 

 

OUH2-S

  Heater  control  switch 

–  Remote way of  turning  ON/OFF  the heater  or using  it  as  Fan  only  in the summer.  We 

recommend this as a minimum control for your heater. This can either be wall mounted or fixed to the back of the heater 
using knockout and screw holes provided. 

 

 

FST2-IN 

Frost thermostat 

– Overrides all controls including  OUH2-S heater control switch “OFF” and turns the heater on 

regardless of how OUH2-S is set. This is used to protect the heated area against low temperatures that may cause damage 
or freezing of water etc. If used the thermostat MUST be mounted out of direct  air flow of the heater and out of reach of 
meddling fingers.  

 

 

RST2-IN

 Thermostat. Can be used with or without the OUH2-S switch this remote thermostat can be used instead of the 

internal  thermostat, handy  when heaters are mounted high or in  positions  where access to  the internal thermostat  is not 
easy.  Mount  out  of  direct  air  flow  of  any  heater  this  thermostat  can  turn  On  /  Off  the  system  depending  on  the  ambient 
temperature. If remote thermostats are used turn up the internal thermostat to full allowing the external t hermostat to control 
the heater.

  

 

 

RST-TP

 Tamperproof Thermostat. Used exactly the same as the RST2-IN but temperature adjustment is concealed. 

 

 

PROSTAT4

 The PROSTAT4 thermostat is a highly accurate  electronic temperature controller suitable for heavy duty use 

in public areas. There are two temperature settings switchable through a push button and integral countdown timer. Optional 
remote sensors are available if temperature control is required away f rom the controller. 

 

 

PROTIM-7

 

7 Day programmable timer. This timer will only allow the heating to operate during the “ON” time settings. During 

“OFF” period there is a “Boost” button that with one press allows heating to operate for 1 hour or with 2 presses 2 hours 
before turning off. The boost can be cancelled by pressing 

the “Boost” button a third time.  

 

 

RT16

 Digital Thermostat is a 7 Day, 6/1 Day or 5 / 2  Day programmable room thermostat which offers four time and temperature 

changes each day. You may also install a remote sensor if you wish to install the thermostat in a different location to the heaters. 
All settings are stored in the controller with battery back-up.

 

 

If you connect heaters in a Master / Slave configuration (See Section 6) controls are only added to the  master heater and all 

the slave heater(s) will follow the master. 

 

 

OUH2-S 

Heater Control Switch 

FST2-IN 

Frost Thermostat 

PROTIM-7 

7 Day Time Switch 

RST2-IN 

Thermostat 

RST-TP 

Tamperproof Thermostat 

RT16 

Digital Thermostat  

PROSTAT4 

2 Set Point Thermostat 

Summary of Contents for OUH2 Series

Page 1: ...or use only The controls and heaters may be fed from a different source and it is essential that all circuit breakers feeding the heating system are isolated prior to any work being carried out on any...

Page 2: ...tside walls along the most exposed part of the building which is normally subjected to the prevailing winds see pictures at bottom of page MULTI FUNCTIONAL BRACKET Using the pictures above and to the...

Page 3: ...ter in mounting position 7 8 or 9 you MUST remove the 2 side panels turn them around 180 and reinstall them Would you also please turn around the front guard so our Logo reads correctly Many Thanks 3...

Page 4: ...een terminals L1 L2 L2 L3 can be found with this instruction leaflet Cable Sizes OUH2 03 3kW Use minimum 1 5mm 3 Core Mains Cable see note above OUH2 05 5kW Use 4mm 3 Core Mains Cable see note above O...

Page 5: ...mote thermostats are used turn up the internal thermostat to full allowing the external thermostat to control the heater RST TP Tamperproof Thermostat Used exactly the same as the RST2 IN but temperat...

Page 6: ...TAT Use 1 0mm 4 core cable Connections Colours for reference only Connect Black wire Terminal 10 of Heater and Terminal 3 on Frost Thermostat Connect Brown Live wire Terminal 11 of Heater and Terminal...

Page 7: ...Earth connection on Control Switch HEATER to THERMOSTAT Connect Black wire Terminal 5 of Heater and Terminal 1 on Thermostat Please note Black wire can be joined in the control switch using a suitabl...

Page 8: ...rminal 1 of Heater and Terminal L on Programmable Timer 230V Live connection Add a Link cable 1mm between Timer L connection and Timer Sin connection Connect Black wire Terminal 2 of Heater and Termin...

Page 9: ...nd still linked as Master Slaves If Using RCD Residual Circuit Device all Heaters connected in a Master Slave arrangement MUST be supplied from the same RCD and not multiple RCD s Multiple MCB s for e...

Page 10: ...nnect Black wire Terminal 6 of Master heater and Terminal 6 of first Slave heater Connect Grey wire Terminal 7 of Master heater and Terminal 7 of first Slave heater Connect Green Yellow wire Terminal...

Page 11: ...g can damage the heater and is not covered by the guarantee 9 TROUBLE SHOOTING AND SOLUTIONS Wall thermostat does not work correctly in a Master Slave set up or single heater Check that you have turne...

Page 12: ...t losses from the entire area you are heating If you are in any doubt please contact BN Thermic and we can carry out a quick check for you Temperature rise OUH2 industrial fan heaters warm a space by...

Reviews: