Typical set up 

There are various options for connecting controls, master and slave units together. 

Here is one example. 

 

 

 

 

 

 

 

 

Connect the mains wire to each heater as per section 4. 

Decide which heater is going to be the master heater and connect the controls to it as per section 5. 

Link the master to the first slave as per instructions on next page. 

Link first slave to second slave as per drawing on next page etc etc. 

 

Linking Heater in a Master / Slave Configuration  

 

Do NOT use power tools to undo or do up the terminal screws. 

 
Linking Master Heater to First Slave Heater - 

Use 1.0mm² 3 core cable 

Connections 

– (Colours for reference only) 

Connect Black wire 

– Terminal 6 of Master heater and Terminal 6 of first Slave heater. 

Connect Grey wire 

– Terminal 7 of Master heater and Terminal 7 of first Slave heater. 

Connect Green / Yellow wire 

– Terminal E or 

of  Master  heater  and  Terminal E or 

of first Slave heater. 

 
Linking Further Slave Heaters - 

Use 1.0mm² 3 core cable 

Daisy chain slave heaters as per drawing above (Maximum number of slave heaters is 15) 
 

PLEASE CHECK ALL CONNECTIONS BEFORE TURNING ON AS INCORRECT WIRING IS NOT COVERED BY THE GUARANTEE 

 

 

MASTER 

Heater 

SLAVE

 

Heater 

SLAVE

 

Heater 

SLAVE

 

Heater 

MAINS 

Supply 

MAINS 

Supply 

MAINS 

Supply 

MAINS 
Supply 

The controls and heaters may be fed from a different 
source  and  it  is  essential  that  all  circuit  breakers 
feeding the heating system are isolated prior to any 
work being carried out on any of the heaters in the 
system.  

10 

Summary of Contents for OUH2 Series

Page 1: ...or use only The controls and heaters may be fed from a different source and it is essential that all circuit breakers feeding the heating system are isolated prior to any work being carried out on any...

Page 2: ...tside walls along the most exposed part of the building which is normally subjected to the prevailing winds see pictures at bottom of page MULTI FUNCTIONAL BRACKET Using the pictures above and to the...

Page 3: ...ter in mounting position 7 8 or 9 you MUST remove the 2 side panels turn them around 180 and reinstall them Would you also please turn around the front guard so our Logo reads correctly Many Thanks 3...

Page 4: ...een terminals L1 L2 L2 L3 can be found with this instruction leaflet Cable Sizes OUH2 03 3kW Use minimum 1 5mm 3 Core Mains Cable see note above OUH2 05 5kW Use 4mm 3 Core Mains Cable see note above O...

Page 5: ...mote thermostats are used turn up the internal thermostat to full allowing the external thermostat to control the heater RST TP Tamperproof Thermostat Used exactly the same as the RST2 IN but temperat...

Page 6: ...TAT Use 1 0mm 4 core cable Connections Colours for reference only Connect Black wire Terminal 10 of Heater and Terminal 3 on Frost Thermostat Connect Brown Live wire Terminal 11 of Heater and Terminal...

Page 7: ...Earth connection on Control Switch HEATER to THERMOSTAT Connect Black wire Terminal 5 of Heater and Terminal 1 on Thermostat Please note Black wire can be joined in the control switch using a suitabl...

Page 8: ...rminal 1 of Heater and Terminal L on Programmable Timer 230V Live connection Add a Link cable 1mm between Timer L connection and Timer Sin connection Connect Black wire Terminal 2 of Heater and Termin...

Page 9: ...nd still linked as Master Slaves If Using RCD Residual Circuit Device all Heaters connected in a Master Slave arrangement MUST be supplied from the same RCD and not multiple RCD s Multiple MCB s for e...

Page 10: ...nnect Black wire Terminal 6 of Master heater and Terminal 6 of first Slave heater Connect Grey wire Terminal 7 of Master heater and Terminal 7 of first Slave heater Connect Green Yellow wire Terminal...

Page 11: ...g can damage the heater and is not covered by the guarantee 9 TROUBLE SHOOTING AND SOLUTIONS Wall thermostat does not work correctly in a Master Slave set up or single heater Check that you have turne...

Page 12: ...t losses from the entire area you are heating If you are in any doubt please contact BN Thermic and we can carry out a quick check for you Temperature rise OUH2 industrial fan heaters warm a space by...

Reviews: