WEEE REGULATIONS:
This appliance bears the symbol of the crossed waste bin. This indicates that, at the end of its useful life, it must not be disposed of
as domestic waste, but must be taken to a collection centre for waste electrical and electronic equipment. It is the user's
responsibility to dispose of this appliance through the appropriate channels. Failure to do so may incur penalties established by laws
governing waste disposal.
BN Thermic Ltd,
34 Stephenson Way,
Crawley, RH10 1TN
Tel: +44 (0) 1293 547361
www.bnthermic.co.uk
k) Insert the wires of the new lamp through the holes in the heater body to the electrical box and reconnect them into the terminals.
Ensure that the terminals are tightened correctly to make a good electrical connection.
l)
Re-assemble in the opposite order making sure all the parts are replaced and the guards are in position.
❑
WARNING!
Failure to reassemble all the parts and use the guards will invalidate any remaining guarantee and may make the unit
dangerous.
6.2 TO REPLACE CENTRE LAMP
a) Make sure the heater is isolated and disconnect from the power supply, wait until the body of the heater has cooled down.
b) Remove both end caps by undoing the 2 socket head screws at each end.
c) Slide out both the end cover plates, remove the guards and end reflectors.
d) Unclip both end lamps from their spring clips, allowing the lamp to move forward clear of the back reflector.
e) Unclip the reflectors from the heater casing and remove.
f) Now slid out the remaining 2 cover plates
making sure you don’t drop the guard from the centre lamp. Gently remove the centre
guard.
g) Remove both end reflectors from the centre lamp.
h) Remove the centre lamp back reflector by getting your fingers behind the reflector and unclipping it from its locating slot.
i)
Disconnect the faulty lamp wires from the terminals located in the electrical box on the rear of the heater, and then remove the lamp.
j)
Insert the wires of the new lamp through the holes in the heater body to the electrical box and reconnect them into the terminals.
Ensure that the terminals are tightened correctly to make a good electrical connection.
k) Re-assemble in the opposite order making sure all the parts are replaced and the guards are in position.
❑
WARNING!
Failure to reassemble all the parts and use the guards will invalidate any remaining guarantee and may make the unit
dangerous.
7. SPARES
Note:
Spare are available from your distributer
Please quote the following Lamp codes when requesting spares
Heater Model
HLW45*G
HLW45*M
Left Lamp Code
RL15GW/4
RL15MW/4
Centre Lamp Code
RL15GW
RL15MW
Right Lamp Code
RL15GW/4
RL15MW/4
NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts
without prior notice.
IMPORTANT:
No liability is accepted for incorrect use of this product.
WARRANTY:
Your BN Thermic product is guaranteed for one year from date of purchase. We
will repair or replace at our discretion any part found to be defective. We cannot assume any
consequential liability. This guarantee in no way prejudices your rights under common law and is
offered as an addition to consumer liability rights.
REGISTER:
Activate your warranty by registering online at www.bnthermic.co.uk and retain
this installation data for future reference.
HWP2-45BINS-v02