2. INTRODUCTION & SPECIFICATION
This heater produces a totally dry heat, no condensation, no gas, no fumes and no smell. It reaches maximum heat output within seconds of being
turned on and has a highly polished aluminum reflector for maximum heat efficiency. It adjusts horizontally through 90° while mounted. And is Ideal
for industrial or domestic applications, IP44 rated.
Model
HB-1500
Power
1500W
Input supply
220-240 Volt 1.5KW 50Hz Single phase 6.5amps
Min. Operating Distance
1000mm
Dimensions
410mm x 120mm x 140mm
Mounting Bracket Stand Off
45mm
Minimum Mounting Height
1.8m
3. MOUNTING INSTALLATION
3.1 WALL MOUNTING (fig.1)
IMPORTANT!
The following points should be noted:
The heater
should always have a minimum clearance of 500mm from a
ceiling and at least 1000mm from any object.
IMPORTANT!
Ensure that the mounting surface is capable of
supporting the weight of the heater.
IMPORTANT!
The heater should be mounted horizontally where
possible or at a maximum angle of 35 degrees from the horizontal.
IMPORTANT!
The mounting bracket must be sufficiently earthed.
3.1.1 Remove the wall mounting bracket from the heater by removing the
two bolts from either end of the bracket.
3.1.2 Before drilling, ensure that there are no wires or water pipes in the
area where the heater is to be placed.
3.1.3 Use the bracket as a template. Fix the metal bracket to the wall by
means of the three holes and appropriate fixings (not supplied).
3.1.4 Refit the heater back onto the bracket and secure with the two bolts.
3.1.5 Adjust the angle of heater to direct heat where required, between
45° and 90° (see fig.1).
3.2 PARASOL MOUNTING
Ensure the heater is at least 500mm away from the
canvas/material of the parasol.
IMPORTANT!
The Mains Cable must not touch or lie on the back of
the heater.
IMPORTANT!
The mounting bracket must be sufficiently earthed.
3.3 ELECTRICAL CONNECTION
3.3.1 Please make sure you have read the Safety instructions and you are a suitably qualified electrician before continuing.
3.3.2 UK ONLY
– If connecting to a 13A Plug
a) Connect the GREEN/YELLOW earth wire to the earth terminal ‘E’.
b) Connect the BROWN live wire to the live terminal ‘L’.
c) Connect the BLUE neutral wire to the neutral terminal ‘N’.
d) After wiring, check that there are no bare wires, that all wires have been correctly connected, that the cable outer insulation extends
beyond the cable restraint and that the restraint is tight.
3.3.3
Connection to a Switched Fused Spur / Isolator.
a) Connect the GREEN/YELLOW earth wire to the earth connection.
b) Connect the BROWN live wire to
the live connection.
c) Connect the BLUE neutral wire to
the neutral connection.
d) After wiring, check that there are
no bare wires, all wires have
been correctly connected, the
cable outer insulation extends
beyond the cable restraints
and that the restraint is tight.