background image

Document Ref.:  VLRW15BN v1.0

 

 

 

 

Page 2 of 4 

 

 

 2. INTRODUCTION & SPECIFICATION  

 

This heater produces a totally dry heat, no condensation, no gas, no fumes and no smell. It reaches maximum heat output within seconds of being 
turned on and has a highly polished aluminum reflector for maximum heat efficiency. It adjusts horizontally through 90° while mounted. And is Ideal 
for industrial or domestic applications, IP44 rated.

 

 

Model 

HB-1500 

Power 

1500W 

Input supply 

220-240 Volt 1.5KW 50Hz Single phase 6.5amps 

Min. Operating Distance 

1000mm 

Dimensions  

410mm x 120mm x 140mm 

Mounting Bracket Stand Off 

45mm  

Minimum Mounting Height 

1.8m 

 
 
 

 3. MOUNTING INSTALLATION  

 

 

3.1    WALL MOUNTING (fig.1)

 



 

IMPORTANT! 

The  following  points  should  be  noted: 

The  heater 

should  always  have  a  minimum  clearance  of  500mm  from  a 
ceiling and at least 1000mm from any object.

 



 

IMPORTANT!   

Ensure  that  the  mounting  surface  is  capable  of 

supporting the weight of the heater.

 



 

IMPORTANT!   

The  heater  should  be  mounted  horizontally  where 

possible or at a maximum angle of 35 degrees from the horizontal.

 



 

IMPORTANT! 

The mounting bracket must be sufficiently earthed.

 

 

3.1.1 Remove the wall mounting bracket from the heater  by removing the 

two bolts from either end of the bracket.

 

3.1.2 Before drilling, ensure that there are no wires or water pipes in the 

area where the heater is to be placed.

 

3.1.3 Use the bracket as a template. Fix the metal bracket to the wall by 

means of the three holes and appropriate fixings (not supplied).

 

3.1.4 Refit the heater back onto the bracket and secure with the two bolts.

 

3.1.5 Adjust the angle of heater to direct heat where required, between

 

45° and 90° (see fig.1).

 

 

3.2    PARASOL MOUNTING

 

Ensure   the   heater   is   at   least   500mm   away   from   the 
canvas/material of the parasol.

 

 

 



 

IMPORTANT! 

The Mains Cable must not touch or lie on the back of 

the heater.

 



 

IMPORTANT! 

The mounting bracket must be sufficiently earthed.

 

 
 

3.3    ELECTRICAL CONNECTION

 

3.3.1 Please make sure you have read the Safety instructions and you are a suitably qualified electrician before continuing.

 

3.3.2 UK ONLY 

– If connecting to a 13A Plug

 

a) Connect the GREEN/YELLOW earth wire to the earth terminal ‘E’. 
b) Connect the BROWN live wire to the live terminal ‘L’. 
c) Connect the BLUE neutral wire to the neutral terminal ‘N’. 
d) After wiring, check that there are no bare wires, that all wires have been correctly connected, that the cable outer insulation extends 

beyond the cable restraint and that the restraint is tight. 

3.3.3 

Connection to a Switched Fused Spur / Isolator.

 

a) Connect the GREEN/YELLOW earth wire to the earth connection. 
b) Connect the BROWN live wire to 

the live connection. 

c) Connect the BLUE neutral wire to 

the neutral connection. 

d) After wiring, check that there are 

no bare wires, all wires have 
been correctly connected, the 
cable outer insulation extends 
beyond the   cable   restraints   
and   that the restraint is tight. 

 

 
 

 

 

Summary of Contents for HB-1500

Page 1: ... without consulting a suitable qualified electrician Ensure that the mounting bracket is adequately earthed Use of an extension cord is not recommended 1 2 GENERAL SAFETY INSTRUCTIONS Remove all packaging and store it away from children check the package and heater for visible damage or tampering Familiarize yourself with the applications and limitations of the heater Ensure the heater is in good ...

Page 2: ... placed 3 1 3 Use the bracket as a template Fix the metal bracket to the wall by means of the three holes and appropriate fixings not supplied 3 1 4 Refit the heater back onto the bracket and secure with the two bolts 3 1 5 Adjust the angle of heater to direct heat where required between 45 and 90 see fig 1 3 2 PARASOL MOUNTING Ensure the heater is at least 500mm away from the canvas material of t...

Page 3: ...little maintenance is required other than to ensure that there is no excessive build up of dust dirt on the reflectors or emitters as this can cause overheating and premature emitter failure To clean the appliance turn off and disconnect from mains supply allow to cool then wipe with a damp cloth 6 LAMP REPLACEMENT Note Before examining or carrying out any maintenance ensure the heater has cooled ...

Page 4: ...riate channels at the end of its useful life Failure to do so may incur the penalties established by laws governing waste disposal BN Thermic Ltd Stephenson way Three Bridges Crawley RH10 1TN Tel 44 0 1293 547361 Fax 44 0 1293531432 Email sales bnthermic co uk Web www bnthermic co uk NOTE It is our policy to continually improve products and as such we reserve the right to alter data specifications...

Reviews: