5. If the battery pack is fully charged the charger cuts off. The green
LED will give a steady light and indicates the full battery pack.
6. The charger has an internal temperature control that protects the
charger at to high ambient temperature as well as continuous
overload. If this happens the charger will reduce the output power
until recovery.
Status
LED Indicators
LED red
LED green
Stand by
off
slow flash 10% on
Pre charge
off
flash 50% on
Charge
off
flash 50% on
Battery full
off
steady
Error
flash
off
Charge end voltage 42 V +/-1%
Remarks
This charger has a wrong polarity protection. The right polarity is
the base that the charger generates a charge voltage. Depending
on the battery safety board, a battery pack that is discharged
under it’s nominal discharge voltage can’t be charged again. In
this case please contact your battery supplier.
Error through reaching the capacity limit or the precharge limit,
will be reset immediately after removing the battery. Error through
short circuit or wrong polarity will be reset automatically maximum
1min after removing the Problem.
Content
1. Charger with dc cable
2. AC Power cord
3. Operating instructions