16
Climate Control System (IHKR)
The manual system is controlled through the use of bowden cables for air distribution and
electronic control for temperature regulation and blower speed. One stepper motor is used
for the fresh/recirculated air intake.
The IHKR incorporates the following features:
• Fresh air intake grilles integrated into the hood - the fresh air passes through the single
micro filter installed in the center of front bulkhead.
The air then passes through the air duct, which is bolted to the bulkhead, and enters the
heater - A/C unit through the non-return flaps.
41530004
64530002
Intake
Fresh Air