DIAGNOSTICS
The diagnostics page will display any detected faults to the JAYCOMMAND
system.
To clear circuit faults, remove the suspected short and toggle the suspected
output to clear the fault indicator.
1.
For lights, tank heater, water heater, water pump, electric and gas heaters, if
a short occurs on these outputs, a red fault indicator will appear.
2.
The gas water heater has its own warning output. If it signals a fault, a
warning will appear on the gas water heater button.
3.
The motor outputs do not indicate a warning if the wires are shorted.
4.
If a fault occurs on a Climate output (e.g. the compressor output), a fault
icon will appear in the zone. To clear the Climate fault, diagnose that Climate
zone, remove the short, turn the Climate off and then turn back on to reset
the fault display.
40