47
Press and release the button a few times until you see ADVANC
To exit menu, keep pressing the “Back” button until the home screen is seen.
WARNING
The advanced menu is reserved for technical personnel
only and available features vary with some versions of
the BatteryPlus35.
APPENDIX 1 : ADVANCED MENU
Incorrect use of this menu can over charge the battery and cause damage to
property and cause personal injury. If unsure, do not change the default values.
The advanced menu allows installers to fine tune the charging parameter, such as
bulk voltage, bulk time and float time.
Advanced Menu Entry
Press and hold the button until you see SETUP
Bulk Voltage
The bulk voltage is the maximum voltage at which the battery will be charged. This
voltage can be adjusted from 13.6V to 14.6V with increments of 0.1V.
Appendix 1: Advanced Menu
Advanced Menu
WARNING!!!! The advanced menu is reserved for technical personnel only. This
menu is not available for all revisions of the BatteryPlus35.
Incorrect use of this menu can over charge the battery and cause damage to
property and cause personal injury. If unsure, leave as default. Default values can
vary between revisions.
The advance menu allows installers to fine tune the charging parameter, such as
bulk voltage, bulk time and float time.
To exit menu, keep pressing the “Back” button until the home screen is seen.
Bulk Voltage
This is the maximum voltage at which the battery will be charged. This voltage
can be adjusted from 14.0V to 14.4V with increments of 0.1V.
To exit menu, keep pressing the “Back” button until the home screen is seen.
Bulk Time
This is the maximum time the bulk voltage can be applied to the battery.
To exit menu, keep pressing the “Back” button until the home screen is seen.