c, Verifying the Installation
While the system is waiting in stand-
by in the “Tank Full” mode, inspect all of th
e water
connections and make sure there are no leaks (the system should be given 10-20 minutes to
make sure the pressure has stabilized enough). Do not forget to open the top cover of the
system and look for leaks inside.
Again, while the system is in the
“Tank Full” mode, read the “Inlet Pressure” and make sure
that it is above 2.5 bars. (If it is below 2.5 bar a tank will be required)
This is the feed water pressure to the system and it will not operate efficiently under this
pressure. Please see Figure
below to locate the “Inlet Pressure.
If the inlet pressure is above 6 bar a 3/8 inline pressure reducer must be fitted
Inlet pressure