28
Replacement of the UV lamps
The replacement can only be performed
by qualified personnel.
Disconnect the unit from its electrical source.
Once the unit is shut down, rotate and
remove the nozzle. Then, remove the top
cover unscrewing the two screws on the
sides (1).
Disconnect the electrical connector of the
UV OUT lamp (2). Pull the lamp (3) removing
it from its fitting holder—handling it carefully.
Insert the new lamp and reconnect the
connector — handling it carefully.
N.B. For the replacement of UV OUT pipe it’s
not necessary to turn the water off.
Disposal of used UV OUT lamps
The UV lamps contain mercury amalgam.
This allows the disposal of the lamps at a
local waste management site. This way of
disposing is completely identical to the
disposal of neon lamps or energy-savings
lamps. These lamps are nevertheless
registered under the same conditions as the
disinfection lamps.
CAUTION!
The light emitted by the ultra-violet lamp
may cause serious burns to the eyes and
skin.
Do not remove it from its stainless-steel
container – only a qualified technician
should do so.