46
EN
Problem
Potential cause
Potential solution
The burner flame is
weak.
Note:
Do not use
the appliance at
temperatures below
5 °C.
The outside
temperature is higher
than 5 °C and the gas
bottle is less than 25
% full.
Replace the gas
cylinder with a new
one.
The gas hose is bent or
kinked.
Straighten the gas hose
and carry out a leak
test on the gas line.
The control knob is in
the maximum position
(large flame).
Switch the control knob
to the "OFF" position.
Close the gas cylinder
valve. Allow the
appliance to cool down
and check the burner
and burner openings
for blockages.
Carbon deposits
Contamination or
coating on the burner
Clean the burner.
Flame blowback (flame
inside the burner)
The burner openings
are blocked.
Switch the control
knob to the "OFF"
position. Close the gas
cylinder valve. Wait
2 minutes and follow
the instructions for the
ignition process. Try
to ignite the burner
again. If the problem
persists, contact the
manufacturer.
Thick black smoke
Blockage in the burner
Rotate the control knob
to the "OFF" position,
allow the appliance
to cool down to room
temperature, remove
the blockage and clean
the burners internally
and externally.