TROUBLESHOOTING
Problem
Potential cause
Potential solution
The burner does not
ignite.
The control knob is not
in its maximum position
(large flame).
Rotate the control
knob to the maximum
position (large flame).
The gas cylinder valve
is closed.
Or: The gas cylinder is
empty.
Open the gas cylinder
valve.
Replace the gas
cylinder.
The injector (injection
nozzle) is clogged.
Clean or replace the
injector.
Low gas pressure
Replace the gas
cylinder with a new
one.
Air in the gas circuit
Open the gas supply
and vent the gas line
(by pressing the control
knob) for not longer
than 1 minute, or until
you smell gas.
The igniter does not
work.
Ignite the burner with
a match. Replace the
battery or replace the
igniter.
The burner fails to stay
on.
Dirt deposits in the
burner area.
Clean the area
surrounding the burner.
Low flame or no
complete flame circle
around the burner. Low
gas pressure.
The flame-spreader
holes are partially
blocked. Clean the
burner.
The thermocouple does
not work properly.
Replace the
thermocouple.
Low gas pressure.
Replace the gas
cylinder with a new
one.