25
EN
Heater stand and location
• The heater is for outdoor use only. Always ensure that dequate fresh air
ventilation is provided.
• Always maintain proper clearance to combustible materials, i.e. top
100 cm and sides 100 cm minimum.
•
Heater must be placed on level firm ground.
• Never operate heater in an explosive atmosphere like in areas where
gasoline or other flammable liquids or vapors are stored.
100 cm
100 cm
CEILING
W
A
LL
Leakage test
Gas connections on the heater are leak tested at the factory prior to
shipment. A complete gas tightness check must be performed at the
installation site due to possible mishandling in shipment or excessive pressure
being applied to the heater.
• Make a soap solution of one part liquid detergent and one part water.
The soap solution can be applied with a spray bottle, brush or rag. Soap
bubbles will appear in case of a leak.
• The heater must be checked with a full cylinder.
Make sure the safety control valve is in the OFF position.
• Turn the gas supply ON.
•
In case of a leak, turn off the gas supply. Tighten any leaking fittings, then
turn the gas supply on and re-check.
• Never leak test while smoking.