SERVO-DRIVE

SERVO-DRIVE unit will not 
work by pulling or pushing.

SERVO-DRIVE unit will only  
work when pulling – not when 
pushing.

Blum plug-in power supply is 
not connected to the switched 
GFCI outlet.

Power supply interrupted.

Blum plug-in power supply is 
defective. Cabling is defective.

Object is obstructing path.

Blum distance bumper is  
missing or defective.

Max. fill height of drawer has 
been exceeded.

SERVO-DRIVE drive unit 

is defective.

Outlet is connected to a switch 
which is turned off

System is connected to a GFCI 
outlet which has interrupted the 
circuit

   Plug the power supply into 

the switched GFCI outlet

 

 

 Check the circuit  
breaker/fuse box.

 

 If necessary, contact an 
authorized electrician.

 

 Replace the Blum plug-in 
power supply.

 Remove the obstruction.

 

 Attach or replace the Blum 
distance bumper.

   Open the drawer manually.
   Remove the items that are 

too high from the drawer.

   Replace the drive unit.

  Turn the switch back on

 Reset the GFCI outlet

Problems

Possible cause

Remedy


ST-CSDOC-68 Rev Feb 2015

Summary of Contents for Tandem

Page 1: ...SERVO DRIVE Installation instructions including TANDEM plus BLUMOTION adjustments ST CSDOC 68 Rev Feb 2015 ...

Page 2: ...ations without notice 2 SERVO DRIVE Drawer removal Squeeze orange handles on locking devices and pull drawer straight out and up Install SERVO DRIVE distance bumper NOTE Blum distance bumpers provide a travel of 3 mm 1 8 ST CSDOC 68 Rev Feb 2015 ...

Page 3: ...with the lever arm extension pre attached The lever arm extension must be removed for cabinet widths of 305 12 or less 1 Press release button 2 Pull Drive unit adjustment Operating mode display LED Selector switch mode Multiple when set to multiple drive units move simultaneously Single only one drive unit moves standard setting Selector switch power Half use for very small and or light drawers Fu...

Page 4: ...ut notice 4 SERVO DRIVE Installation of bottom bracket 1 Insert locating pins into pre bored holes 2 Secure with wood screws Connect power supply Connect cable with INSERTA cable connectors and cap off with cable end protectors 2 1 ST CSDOC 68 Rev Feb 2015 ...

Page 5: ...pply into switched GFCI outlet Installing cable connector 1 Insert cable for distribution into open slot 2 Insert cable for power into open slot 3 Rotate orange lever to lock into place 4 Slide cable end protector over exposed cable NOTE Ensure piercing pins are not damaged 1 2 4 3 ST CSDOC 68 Rev Feb 2015 ...

Page 6: ...height of drawer has been exceeded SERVO DRIVE drive unit is defective Outlet is connected to a switch which is turned off System is connected to a GFCI outlet which has interrupted the circuit Plug the power supply into the switched GFCI outlet Check the circuit breaker fuse box If necessary contact an authorized electrician Replace the Blum plug in power supply Remove the obstruction Attach or r...

Page 7: ...ront side adjustment is made with the locking devices rotate the rear side adjustment left or right to re align the back of the drawer box with the front Drawer back moves in the same direction as rotation Maximum 1 5 1 16 to left or right tool free New side adjustment 1 Rotate side adjustment left or right equally on both locking devices Drawer front moves in the same direction as rotation with s...