Document #: BPI-PM001-01
7
Installation
An overview of Mechanical and Electrical
Installation instructions is contained in this
section. Details of steps to hang the Model
420 from the ceiling or mount on a shelf are
contained in Appendix A.
Installation Guidelines
Place the Model 420 in the room so that air
flow from the HVAC system, fans or other
air flow systems does not blow directly into
or pull air through the Model 420 air inlet or
clean air outlet.
Ensure a minimum clearance distance of
10’ (3m) from an air handler outlet to the
Model 420 to avoid excessive air flow
through the unit.
Place the unit so that the control panel and
display are visible and accessible.
If multiple Bluezone Model 420 units are
being installed in a room, the following are
recommended guidelines for the placement
of the Bluezone units:
1.
Distribute the units relatively evenly
throughout the space.
2.
Generally spreading the locations
across the available space is good
practice.
3.
Warning: Hang the units from the
ceiling, mount to the wall or on a
shelf/rack to avoid unintended bumping
of the units.
4.
Units hung from the ceiling should be
hung to the level of the lights, but not
below lights to avoid blocking light to
the plants.
5.
Warning: If the unit is located in an
area with foot traffic and there is a
concern that it could be bumped by
personnel, it should be labeled with
colored tape to make it more visible
and reduce the risk of collision.
6.
Warning: Locate the junction
boxes for the units as close as possible
to the units to avoid the risk of hooking
the cord and pulling it out. If the
distance to the junction box is more
than 2’ (0.6 m), the cord should be tied
to the wall, rack, or ceiling to keep it
protected.
Summary of Contents for 420 Series
Page 4: ...Document BPI PM001 01 3 Key Components Figure 1 Bluezone Key Components 2 3 5 4 1 6 ...
Page 7: ...Document BPI PM001 01 6 Figure 4 Wiring Diagram of Model 420 048 Unit ...
Page 10: ...Document BPI PM001 01 9 Figure 6 Illustration of the Ceiling Mount and Shelf Mount ...
Page 13: ...Document BPI PM001 01 12 Figure 8 Display Sequence in Time ...
Page 22: ...Document BPI PM001 01 21 Figure 14 Carefully Slide off Bulb Clips using Nitrile Gloves ...
Page 30: ...Document BPI PM001 01 29 Figure 24 Completed Assembly ...
Page 32: ...Document BPI PM001 01 31 Figure 26 Shelf Mount Dimensions ...
Page 36: ...Document BPI PM001 01 35 Figure 32 Screws Installed into Bluezone Muffler and Fan Cover ...
Page 37: ...Document BPI PM001 01 36 Figure 33 Completely Installed Bluezone Muffler ...