71
INSTALLATION AND OPERATING INSTRUCTIONS · HSI
EN
Programm
Selectable option
Description
Solar
Charger
absorb
current
5 .0A~30 .0A (default)
Set the absorb current of the Solar Charge Control-
ler . (Refer to the Charging Curve)
Solar
Charger
voltage
low DC
cut-off
17 .0V~22 .0V
(default)
If the battery voltage os lower than the set point,
the Solar Charge Controller will close the output .
Solar
Charger
high DC
cut-off
voltage
29 .0V~30 .0V
(default)
If the battery voltage is higher than the set point,
the Solar Charge Controller will close the output .
SYSTEM
Auto re-
start when
overload
occurs
Restart enable .
(default)
Restart enable .
Auto restart
when over
tempera-
ture occurs
Restart disable .
(default)
Restart enable .