Addr
(hex)
Register Name
Default
Value (hex)
R/W Description
01B5
AecKd
0000
R/W Differential part of the auto exposure controller in
percent
Table 5-7: Registers for automatic exposure control
5.8
Registers for Test Commands
Addr
(hex)
Register
Name
Default
Value (hex)
R/W Description
01C0
TestConfig
0000
R/W Bit[1]: 1… Watchdog Test
Bit[2]: 1…Simulate color sensor module failure
Bit[3]: 1…Simulate ToF sensor module failure
Bit[4]: 1…Manually power off camera with UVLO detector
Writing this register must be preceded by writing 0x5E6B
into register CmdEnablePasswd (0x0022)
Table 5-8: Registers for Test Commands
5.9
Registers for Device Update
Addr (hex)
Register Name
Default Value (hex)
R/W
Description
01D1
FileUpdateStatus
0000
R
0…idle
3…out_of_memory
6…file crc error
8…erasing flash
9…flashing
11…erasing failed
12…flashing failed
14…update success
16…header version conflict
18…wrong fw identifier
20…data inconsistent
21…in progress
255…protocol violation
01D9
MaterialNumberLow
R
Material number, low word
01DA
MaterialNumberHigh
R
Material number, high word
Table 5-9: Registers for device update
5.10
Registers for Filter Configuration
Addr
(hex)
Register Name
Default
Value (hex)
R/W Description
01E0
ImgProcConfig
28C0
R/W Bit[0]: 1…enable Median Filter for Distance
Image
Bit[3]: 1…enable Bilateral Filter for Distance
Image
Bit[4]: 1…enable Sliding Average for Distance
Image
Bit[6]: 1…enable wiggling compensation for
Distance Image