Software User Manual - Argos 3D-P320
Last change: 2 February 2016
Version 0.14
© Bluetechnix 2016
Page 47 | 70
5
Register Description
Note
Some critical registers are password protected. To enable the functionality a specific value
must be written to the
CmdEnablePasswd
register in advance to enable the functionality.
This should prevent from accidentally executing certain functions.
5.1
General registers
Addr
(hex)
Register Name
Default
Value
(hex)
R/W Description
0001
Mode0
0001
R/W Bit[0]: 0…Manual Mode, 1…Video Mode
Bit[4]: 1…Manual Trigger (self-clearing bit)
Bit[6]: 1…Clear status register (self-clearing bit)
Bit[11]: 1…3D Snapshot Trigger (self-clearing bit)
0003
Status
0040
R
Bit[2]: 1…Ongoing Calibration
Bit[3]: 1…LIM temperature sensor error
(Temperature sensors not found, or temporary
temperature reading error)
Bit[4]: 1…TIM temperature sensor error
Bit[5]: 1…Calibration data missing
Bit[6]: 1…Factory Regmap was loaded
Bit[8]: 1…Previous firmware version was restored
Bit[9]: 1…LIM over-temperature
Bit[10]: 1…Frame rate or integration time was
limited due to PoE constraints
Bit[11]: 1…Error condition reported by one of the
LIMs, see registers
Lim1Status
and
Lim2Status
for
details
Bit[13]: 1…Color sensor stream error
Bit[14]: 1…Base board temperature sensor error
Bit[15]: 1…TIM error (I2C communication, triggering)
0004
ImageDataFormat
0000
R/W Bit[3:10]:
0 … Distances and Amplitudes
1 … Distances, Amplitudes, and Confidences
2 … Distances, Amplitudes and Color
3 … XYZ Point Cloud
4 … XYZ Point Cloud and Amplitudes
6 … Distances and Color
7 … 4 raw phases (0°,90°,180°,270°)
8 … 4 raw phases (270°,180°,90°,0°)
9 … Distances and XYZ Point Cloud
10 … X Coordinate and Amplitudes
11 … Test mode
12 … Distances
13 … Raw Distances and Amplitudes
21 … Distances, Amplitudes, Confidences, and
Color
0005
IntegrationTime
05DC
R/W Integration Time [µs] (min: 1, max: 24000)
0006
DeviceType
B320
R
Hardware specific identification
0007
DeviceInfo
R
Bit[0-3]: PCB Revision