Software User Manual - Argos 3D-P320
Last change: 2 February 2016
Version 0.14
© Bluetechnix 2016
Page 54 | 70
Addr
(hex)
Register Name
Default
Value (hex)
R/W Description
100 - 30000 … Time for illumination pre-heating
in microseconds
0152
IllPreheatingTimeSeq1 0000
R/W Sequence 1 illumination preheating
0 … No pre-heating
100 - 30000 … Time for illumination pre-heating
in microseconds
NOTE: Sequence 0 illumination preheating time
is set via register
IllPreheatingTime
Table 5-6: Registers for Illumination Pre-heating
5.7
Registers for Automatic Exposure Control
Addr
(hex)
Register Name
Default
Value (hex)
R/W Description
01A9
AecAvgWeight0
4444
R/W Bit[15-12]: Weight for average, area 1
Bit[11-8]: Weight for average, area 2
Bit[7-4]: Weight for average, area 3
Bit[3-0]: Weight for average, area 4
01AA
AecAvgWeight1
44CC
R/W Bit[15-12]: Weight for average, area 5
Bit[11-8]: Weight for average, area 6
Bit[7-4]: Weight for average, area 7
Bit[3-0]: Weight for average, area 8
01AB
AecAvgWeight2
C44C
R/W Bit[15-12]: Weight for average, area 9
Bit[11-8]: Weight for average, area 10
Bit[7-4]: Weight for average, area 11
Bit[3-0]: Weight for average, area 12
01AC
AecAvgWeight3
FC44
R/W Bit[15-12]: Weight for average, area 13
Bit[11-8]: Weight for average, area 14
Bit[7-4]: Weight for average, area 15
Bit[3-0]: Weight for average, area 16
01AD
AecAvgWeight4
CCC4
R/W Bit[15-12]: Weight for average, area 17
Bit[11-8]: Weight for average, area 18
Bit[7-4]: Weight for average, area 19
Bit[3-0]: Weight for average, area 20
01AE
AecAvgWeight5
4444
R/W Bit[15-12]: Weight for average, area 21
Bit[11-8]: Weight for average, area 22
Bit[7-4]: Weight for average, area 23
Bit[3-0]: Weight for average, area 24
01AF
AecAvgWeight6
4000
R/W Bit[15-12]: Weight for average, area 25
01B0
AecAmpTarget
02BC
R/W Auto exposure target amplitude value to which the
controller is controlling to
01B1
AecTintStepMax 0021
R/W Auto exposure maximum change of integration time
percentage. The relative change of the integration time
will be lower than this percentage
01B2
AecTintMax
2710
R/W Auto exposure maximum integration time the controller
calculates
01B3
AecKp
0028
R/W Proportional part of the auto exposure controller in
percent
01B4
AecKi
000F
R/W Integral part of the auto exposure controller in percent