12
6.3.2.4
Do not bend the modules while installing the modules. The mounting parts can not block the cells, do
not scratch the glass surface of the module. It is recommended that the overlapping part of the module and the
clamp should be 11-15mm in width, the length of the fixture should be at least 200mm, and the minimum
thickness of the fixture should be at least 3mm.
6.3.2.5
The position of the clamp is critical to the reliability of the installation. The recommended clamping
range is shown in Table 3:
Table 3 The clamping range of the fixture
Module type
Design Mechanical
Loading/Pa
Safety factor= 1.5
(Positive/ Negative)
A/mm
B/mm
C/mm
E/mm
F/mm
BSMxxxCM5-72SD
BSMxxxPM5-72SD
BSMxxxPMB5-72SD
3600/1600
1959
1983
1076
1096
392±50
400±50
11
~
15
11
~
15
≥200
≥200
BSMxxxPM5-72SDA
BSMxxxPMB5-72SDA
3600/1600
BSMxxxCM5-60SD
BSMxxxPM5-60SD
BSMxxxPMB5-60SD
3600/1600
1639
1076
329±50
11
~
15
≥200
BSMxxxPM5-60SDA
BSMxxxPMB5-60SDA
3600/1600
Note:
A: Length of this type of module.
B: Width of this type of module.
C: The distance of clamp center1 from the edge of
this type of module.
E: Clamped width of the module by the clamp of
this type of module.
F: length of the clamp.
*Tips: Bluesun does not guarantee the consequences caused by incorrect installation methods without following this
installation manual. When you take fixture installation, please pay attention to the following points:
(a) The fixture is mounted on the long side of the modules. (b) The fixture shall not produce shadow on the glass surface
of the modules. (c) The guide rail and the long side of the modules are installed vertically.
6.3.3
Hook installation
(
Suitable for single side double glass modules
)
6.3.3.1
Modules can be attached through the hook on the back side of the module,by fixing the module to the
support rails with M8 bolt(for 60 version of the series ) and M10 bolt(for 72 version of the series ).The module
backside has 4 hooks. (Figure 13)The minimum distance between two modules is 10mm. The hex nut cannot
the fixed on the head of the insert place. The connecting surface of the support must keep smooth. (Figure 14)